======================================================================================================================= 1.3 [released 2021-07-23] ======================================================================================================================= 1.3.2.1 [available 2023-07-07] prerequisite Windows 10 (64 bit), English, version 1809 or newer prerequisite Microsoft .NET Framework 4.7.1 or newer prerequisite Keysight IO Libraries Suite 18.1 or newer supported Microsoft Office Excel 2016, English supported D9021HDMC HDMI Test App ver. 2.37.9.0 supported DSAV334A SW rev. 6.55.00902 supported Pulse Function Arbitrary Generator 81160A Software rev. 2.0.0.0 and Hardware rev. 2.6 supported DSGA FW ver. 1.20 and System ver. 1.11 modification More relaxed eArc detection sequence to allow testing of DUTs with slightly different pattern order. bugfix Missing button "Show Connection..." in the contextual menu of tests HEACT 5-19 and HEACT 5-20. bugfix Procedures were running "Online", even if the required scope app was not connected. known issue In eARC test HFR5-1-9, CM_Noise_Floor measurement is made but it is NOT shown in an additional screenshot in the test report. 1.3.1.1 [available 2023-01-24] prerequisite Windows 10 (64 bit), English, version 2004 or newer prerequisite Microsoft .NET Framework 4.7.1 or newer prerequisite Keysight IO Libraries Suite 18.1 or newer supported Microsoft Office Excel 2016, English supported D9021HDMC HDMI Test App ver. 2.37.9.0 supported DSAV334A SW rev. 6.55.00902 supported Pulse Function Arbitrary Generator 81160A Software rev. 2.0.0.0 and Hardware rev. 2.6 supported DSGA FW ver. 1.20 and System ver. 1.11 bugfix Sometimes the eArc detection sequence timed out too early. known issue In eARC test HFR5-1-9, CM_Noise_Floor measurement is made but it is NOT shown in an additional screenshot in the test report. 1.3.0.1 [available 2021-07-23] prerequisite Windows 10 (64 bit), English, version 2004 or newer prerequisite Microsoft .NET Framework 4.7.1 or newer prerequisite Keysight IO Libraries Suite 18.1 or newer supported Microsoft Office Excel 2016, English supported D9021HDMC HDMI Test App ver. 2.37.9.0 supported DSAV334A SW rev. 6.55.00902 supported Pulse Function Arbitrary Generator 81160A Software rev. 2.0.0.0 and Hardware rev. 2.6 supported DSGA FW ver. 1.20 and System ver. 1.11 modification Additional information has been added to the connection diagram description to make the instructions clearer modification Aditional description has been added to eARC discovery pop-up dialog when SL-870 is used modification Test 5-1-13 popup contains the image of the eARC signal which should be seen on the oscilloscope modification Connection establishment between scopeapp and ValiFrame is made faster known issue In eARC test HFR5-1-9, CM_Noise_Floor measurement is made but it is NOT shown in an additional screenshot in the test report ======================================================================================================================= 1.2 [released 2021-05-07] ======================================================================================================================= 1.2.0.10 [available 2021-05-07] supported D9021HDMC HDMI Test App ver. 2.37.9.0 supported DSAV334A SW rev. 6.55.00902 supported Pulse Function Arbitrary Generator 81160A Software rev. 2.0.0.0 and Hardware rev. 2.6 supported DSGA FW ver. 1.20 and System ver. 1.11 information Removed HEC Support information Adding the support for 1134B and 1130 probes information Adding the missing low speed cable connection to J104 on 81150 board in the connection diagrams for ARC Tx tests bugfix Audio threshold of 0 V caused invalid trigger setting for ARC Rx tests, which is fixed bugfix Missing jumper settings description is updated in the eARC Tx connection diagrams bugfix Heartbeat trigger and termination voltage were not set on the scopeapp correctly for eARC test HFR5-1-15 bugfix Automation of power supply in test HEACT 5-20 was not happening even when the power supply was connected in the Station Configurator modification N5449A high impedance adapters is added to the description of the required connection diagrams which can be used with DSO X and V series oscilloscopes modification Displaying both channel 1 and channel 3 on the oscilloscope for the test HFR5-1-13 as is mentioned in the CTS modification All calibrations and tests use channel 1 and channel 3 of the oscilloscope modification Improvement of the connection interface of oscilloscope application so that no error is generated when Valiframe is started very soon after the Station Configurator is closed known issue Incorrect device detected pop up appears when N5449A high impedance adapter is used for the ARC DC operating voltage tests ======================================================================================================================= 1.0 [released 2020-04-29] ======================================================================================================================= 1.0.1 [available 2020-09-29] Information Updated CodeMeter Runtime to version 7.10a to fix vulnerabilities CVE-2020-14513, CVE-2020-14519, CVE-2020-14509, CVE-2020-14517, CVE-2020-16233, and CVE-2020-14515 1.0.0 [available 2020-04-29] tested with DSOX92504A Oscilloscope Firmware Version: 6.50.01004 tested with DSO91304A Oscilloscope Firmware Version: 6.50.01004 tested with BIT-3000 DSGA Firmware Version 1.20 tested with Pulse Function Arbitrary Generator 81160A Software Version: 2.0.0.0 and Hardware Version: 2.6 tested with D9021HDMC TX scope app Version: 2.34.0.0 known issue Ethernet Transition Time calibration executes online even if no instruments are connected known issue User Name and Comments section settings in Configure DUT Dialog are not saved in Valiframe Project file (.vfp) new First ValiFrame HDMI ARC N5991 product release new Using BLM (BitifEye License Manager) licensing