===== ValiFrame HDMI PHY Module ===== ======================================================================================================================= 1.3 [released 2023-12-22] ======================================================================================================================= 1.3.3.0 [available 2024-02-02] prerequisite Windows 10 (64 bit), English, version 1809 or newer prerequisite Microsoft .NET Framework 4.8 or newer prerequisite Keysight IO Libraries Suite 18.1 or newer supported Microsoft Excel rev. 2021, English supported D9021HDMC HDMI Test App rev. 2.40.2019.0 supported Keysight Infiniium System Software rev. 6.74.00402 supported Keysight Infiniium UXR-Series System Software rev. 11.50.00601 supported Keysight AWG M8195A rev. 4.2.2.0-2 supported Keysight AWG M8197A rev. 4.2.2.0-1 bugfix 'Data Jitter (on data) Calibration' failed for all resolutions. bugfix Some procedures did not update the compliance status correctly. known issue In very rare corner cases, a procedure that is compliant may still be marked as not compliant. known issue Skew setting is not working for specific low bit rates for Test HF2-51. known issue Waveform Data calculation is not working for HFR2-4. Running HFR2-4 will break saved calculations for HFR2-1 to HFR2-3. known issue HFR7-21 is not working with D9021HDMC HDMI Test App rev. 2.40.2019.0. In order to make it run, you have to enter the following path at the oscilloscope: "C:\ProgramData\Keysight\Infiniium\Apps\HDMIHEACTest\app\config\TransferFunction\CTS21". Now you have to rename all files that start with "WT_HDMI-21_RecepFRLEqu...". Change to "WT_HDMI-21_RFRLEqu...". known issue 'Fall/Rise Time Calibration' shows incomplete result below last entry. known issue 'Calibration Data Version' property is shown with additional apostrophes. information The Compliance Mode of this app has been extensively tested. The Expert Mode, however, is not tested to such a great extent and may therefore still contain bugs. information Updated CodeMeter Runtime to version 7.60a to fix vulnerabilities CVE-2021-20093 and CVE-2021-20094. 1.3.2.0 [available 2024-01-30] prerequisite Windows 10 (64 bit), English, version 1809 or newer prerequisite Microsoft .NET Framework 4.8 or newer prerequisite Keysight IO Libraries Suite 18.1 or newer supported Microsoft Excel rev. 2021, English supported D9021HDMC HDMI Test App rev. 2.40.2019.0 supported Keysight Infiniium System Software rev. 6.74.00402 supported Keysight Infiniium UXR-Series System Software rev. 11.50.00601 supported Keysight AWG M8195A rev. 4.2.2.0-2 supported Keysight AWG M8197A rev. 4.2.2.0-1 bugfix Fixed saving of compliant 'Fall/Rise Time Calibration'. bugfix In some rare corner cases not all properties were handled correctly during loading of .vfc/.vfp files. bugfix Fixed the compliant header on the summary and instruments page of exported results. known issue In very rare corner cases, a procedure that is compliant may still be marked as not compliant. known issue Skew setting is not working for specific low bit rates for Test HF2-51. known issue Waveform Data calculation is not working for HFR2-4. Running HFR2-4 will break saved calculations for HFR2-1 to HFR2-3. known issue HFR7-21 is not working with D9021HDMC HDMI Test App rev. 2.40.2019.0. In order to make it run, you have to enter the following path at the oscilloscope: "C:\ProgramData\Keysight\Infiniium\Apps\HDMIHEACTest\app\config\TransferFunction\CTS21". Now you have to rename all files that start with "WT_HDMI-21_RecepFRLEqu...". Change to "WT_HDMI-21_RFRLEqu...". known issue 'Fall/Rise Time Calibration' shows incomplete result below last entry. known issue 'Calibration Data Version' property is shown with additional apostrophes. information The Compliance Mode of this app has been extensively tested. The Expert Mode, however, is not tested to such a great extent and may therefore still contain bugs. information Updated CodeMeter Runtime to version 7.60a to fix vulnerabilities CVE-2021-20093 and CVE-2021-20094. 1.3.1.0 [available 2024-01-26] prerequisite Windows 10 (64 bit), English, version 1809 or newer. prerequisite Microsoft .NET Framework 4.8 or newer. prerequisite Keysight IO Libraries Suite 18.1 or newer. supported Microsoft Excel rev. 2021, English. supported D9021HDMC HDMI Test App rev. 2.40.2019.0. supported Keysight Infiniium System Software rev. 6.74.00402. supported Keysight Infiniium UXR-Series System Software rev. 11.50.00601. supported Keysight AWG M8195A rev. 4.2.2.0-2. supported Keysight AWG M8197A rev. 4.2.2.0-1. bugfix Compliant procedures were shown as not compliant. known issue In very rare corner cases, a procedure that is compliant may still be marked as not compliant. known issue Skew setting is not working for specific low bit rates for Test HF2-51. known issue Waveform Data calculation is not working for HFR2-4. Running HFR2-4 will break saved calculations for HFR2-1 to HFR2-3. known issue HFR7-21 is not working with D9021HDMC HDMI Test App rev. 2.40.2019.0. In order to make it run, you have to enter the following path at the oscilloscope: "C:\ProgramData\Keysight\Infiniium\Apps\HDMIHEACTest\app\config\TransferFunction\CTS21". Now you have to rename all files that start with "WT_HDMI-21_RecepFRLEqu...". Change to "WT_HDMI-21_RFRLEqu...". information The Compliance Mode of this app has been extensively tested. The Expert Mode, however, is not tested to such a great extent and may therefore still contain bugs. information Updated CodeMeter Runtime to version 7.60a to fix vulnerabilities CVE-2021-20093 and CVE-2021-20094. 1.3.0.12 [available 2023-12-22] prerequisite Windows 10 (64 bit), English, version 1809 or newer. prerequisite Microsoft .NET Framework 4.8 or newer. prerequisite Keysight IO Libraries Suite 18.1 or newer. supported Microsoft Excel rev. 2021, English. supported D9021HDMC HDMI Test App rev. 2.40.2019.0. supported Keysight Infiniium System Software rev. 6.74.00402. supported Keysight Infiniium UXR-Series System Software rev. 11.50.00601. supported Keysight AWG M8195A rev. 4.2.2.0-2. supported Keysight AWG M8197A rev. 4.2.2.0-1. new Support of HF2-51. new Added tooltip and helper window explaining the meaning of sequencer icons. new Improved visibility of warnings and critical errors. The number of warnings and critical errors is now displayed: - as additional log entries at the end of each run, - in the run end window and - in the status bar. new Nodes in the sequence tree in ValiFrame are now selectable and deselectable by pressing the spacebar. new The results of procedures now show a compliance mode indicator. This indicator also takes into account the compliance state of all relevant calibrations. Procedures that run offline are considered not compliant. new Exporting results is now possible from any node in the ValiFrame sequence tree using the context menu. new License Certified Time will be updated automatically at the start-up of ValiFrame. new It is now possible to export the log file from the context menu of the log window in the main window of ValiFrame K1. The functionality to export the log file is also accessible from the remote API. new Added a button in the About Dialog to directly navigate to the API documentation. new It is now possible to query the Application Version from the ValiFrame remote API. new Added a new context menu option to group logs based on log context. new Added "Required Calibration Data" context menu popup. new Added an additional header to procedure result reports indicating if a result was created in conditions where compliance cannot be guaranteed. Compliance cannot be guaranteed for calibration data created before the introduction of this feature. It will be marked as Compliant = "False". That does not necessarily mean it was created in a non-compliant way, just that the result report does not contain the data necessary to guarantee compliance. new Added indicators in the result reports of each procedure for the following information: * software version, * calibation data version(s) if there is any required calibration data, * whether the result was created in conditions where compliance can be guaranteed, * reason(s) why compliance cannot be guaranteed if that is the case. new The same indicators that were added to individual result reports were also added to the summary table of exported results workbooks. modification Updated HFR7-1 & HFR7-22 to GCTS ver. 2.1g. modification Automotive Receiver Setting removed. modification N1080H04 TMDS fixture removed. modification N5380A/B Probes moved to expert mode. modification Protocol tests moved to expert mode. modification 2/4 Channel Mode setting only for Cable and non-CAT3 tests. modification Added ground information to connection diagrams for sink tests. modification Removed Automotive Setting from Cable product type. modification Probes not shown in property list anymore. modification Added TMDS Clock in TMDS calibrations and tests. modification FRL waveform calculation removed from expert mode. modification Changed 2/4 Connection to 2/4 Lanes. modification Cable emulator now visible as a 'Read only' property for Waveform calculation and HFR7-21. modification Moved Cable Fall/Rise time to upper level. modification Renamed Fall/Rise time with uppercase T to match Sink Rise/Fall Time calibration. modification Removed the space in HF/HFR test IDs. modification 'Check measured TMDS character rate' setting is actively set to 'No' on the Tx App. modification HFR2-4 now reports a fail instead of aborting if there is an issue. modification Added CTS/MOI revisions for each test procedure. modification Renamed HF2-7 'Deep Color' as 'Video Timing 2160p Deep Color'. modification Fixed various spelling mistakes and improved property descriptions. modification Increased number of 'LookUp Bits' for FRL InterPair-Skew test. modification More detailed information about instruments used to execute specific calibrations or tests are provided during the execution and in the results windows (right-click on results - select "Show Results"). modification The instrument summary table in workbook export has been improved. Previously, the instruments that were connected at the time of the export were shown in the table. From now on instruments that were connected during the execution of specific calibrations or tests are displayed. If calibrations or tests were run with a previous version of the software, the instrument table will be empty. modification A new status indicator for the maintenance exists in the ValiFrame main window. The indicator is yellow 90 days before the maintenance contract ends. If the maintenance contract has expired, the indicator will be red. More information is visible in the ValiFrame About window. modification The ValiFrame About window shows the product information and not the features. This makes it easier to identify which products are installed or need maintenance renewal on your machine. modification Improved the handling of licenses that are installed in different containers on the same machine. modification UI changes of helper window explaining the meaning of sequencer icons. Context menu entry is now called. modification HTML reports are now generated as a single file. Styles, scripts and images are embedded in that file. modification Improved formatting of summary table in exported HTML results. Entries in the result column are now color coded. modification Warning messages in StationConfigurator "Check Connections" turn the matching instrument line yellow. modification Warnings about unsupported instrument models and untested firmware revisions have been made more precise and clearer by splitting them into separate messages. modification Disabled the option to close the results view of an ongoing test run. modification When attempting to start an installer, the required OS is now correctly checked: Windows 10, 64bit, version at least 2004. Also corrected the user message in case of a mismatch. modification Installers now check (by looking at the available licenses) if installing the product would push a product or feature past maintenance end. If yes, a warning is presented to the user. modification Added tooltip hint for maintenance status label. modification Lowered OS requirements to Win10 x64 version 1809. modification When ValiFrame is denied access to the temporary SigTest workspace folder because another service is interacting with the folder, ValiFrame now starts a retry to access it instead of sending an exception. modification Improved EZJIT parsing. Unrecognized tokens will be output as a log warning. modification Removed ValiFrameRemoteGui and all C# example code from the installer. modification Make loading of M8000 states more robust. modification Cached maximum instrument bandwidth to avoid unnecessary SCPI queries. modification The auto-generated documentation for the ValiFrame remote API is now included in the installer. Also a start menu shortcut to it is generated. modification Improved Logging using the Iso format for the date and added tabs as dividers. modification Introduced a new logging level called "Context" which is used to log context start/end into the log file. Its not visible in the UI. modification Added standalone tool to transform a ValiFrame log into a JSON file. modification Only test results are saved in vfp files. Calibration results are not saved. modification Connection Diagram windows now always appear and stay in front of the ValiFrame main window. modification The meaning of the parameter Compliant has been changed. The results of a procedure are now compliant if a) it was run in compliance mode or b) it was run in expert mode but the values of the parameters that can be changed in expert mode had their default values. modification Removed "SetResult" methods from ValiFrameRemote. They had been declared obsolete 3 years ago. modification Added a new progress log entry that traces the estimated duration in procedures that contain a fixed number of steps. modification Introduced a new enum for the MemorySource of the M8195A. modification Introduced a new SCPI log file, which can be found in the logging directory, recording all SCPI commands and queries in addition to all the regular log file entries. Big data from SCPI commands and queries is truncated to keep the file size manageable. modification Remote Instrument Server now logs into the folder ProgramData\BitifEye\ValiFrameK1\Tmp. modification Changed script parser to report an error if a pattern block is smaller than the minimum size. modification Out parameter methods from ValiFrameRemote have been marked as obsolete. New return value methods were added. modification Modified the default start page of the Remote Api Doc and also included 2 hyperlinks to the namespace and the class on the index page. modification Removed irrelevant SigTest result details from the logfile. bugfix Skew calibration showed wrong diagram at second step. bugfix Connection diagram for sink tests was wrong. bugfix Termination description for N7010A probes was not working. bugfix FRL waveform calculation was added twice. bugfix Properties from the GUI were not saved for the next run. bugfix Intra-Pair Skew Test & Jitter Characterization Test entered an infinite loop in Offline mode. bugfix AWG outputs were not disabled when requesting connection change in skew calibration. bugfix Connection description duplication for cable tests. bugfix Legacy property names were not supported when loading old vfp files. bugfix In Offline mode, measurement of cables passed if the red button in the dialog was pressed and 'HPD +5V_Power' was set to true. bugfix Connection diagram instructed a connection to TPA-P fixtures to be made for Cables. bugfix Custom BER Reader did not work for TMDS Tests. bugfix Spelling error during FRL tests: asyncrhonous to asynchronous. bugfix Waveform Data calculation now working for most tests. bugfix Saving and loading the FRL project file was changing BER Reader type. bugfix Username was not saved. bugfix Exceptions were thrown for cable tests in combination with N2803A probes. bugfix The procedure properties "Procedure Error Case Behavior", "Procedure Failed Case Behavior", and "Repetitions" did not work for some procedures. bugfix Settings from Station Configurator were not applied in ValiFrame. bugfix Installed version check in installer was not working properly. bugfix Exporting test results did not work if MS Excel was not installed. bugfix Bundled licenses were not shown in the ValiFrame About window. bugfix ComboBoxes in the ValiFrame property grid sometimes did not open correctly. bugfix When a calibration procedure failed or was aborted, calibration table properties and values could be corrupted for the rest of the program runtime. Restarting ValiFrame restored the correct values. bugfix Expiration dates for demo licenses were not displayed in the ValiFrame About window and in the logfile. bugfix Sheets in exported result workbooks were in the wrong order if the target format was an Excel file. bugfix The ValiFrame Remote Interface was reporting an InvalidProgramException while ending the application. bugfix The OK button in the critical error window was unreachable due to incorrect scaling on high DPI machines. bugfix The ValiFrame main window did not close properly when report subwindows were open. bugfix Graphs were missing when exporting a single report as HTML. bugfix Fixed instrument selection in the StationConfigurator. bugfix Fixed exception when exporting to Excel. bugfix Fixed. On attempting to install ValiFrame while the software was running, an incorrect message was displayed about which software was already running. bugfix Fixed wrong assignment of parameter value in VFCalTable bugfix Fixed misleading text in warning messages about supported instrument firmware revisions. bugfix Fixed an issue that prevented the gathering of all available relevant data in case of a crash. bugfix The "Unreleased Software" banner has been moved to the right of the window and made less wide. The main window of ValiFrame has now a minimum size of 600x600. These changes were done so that the banner is not overlapping other controls when the window is shrunk. bugfix Fixed. In some cases the warning message about an unsupported firmware version was incomplete. bugfix Corrected connection points for SP8TB terminated switch connection image. bugfix Fixed duplicated 'Transfer Functions' folder name when applying transfer function. bugfix Fixed connection diagram button displayed incorrectly on certain screens. bugfix Fixed spelling in connection diagram dialog. bugfix Could not connect to BIT-2100B due to a parsing error. bugfix Fixed the connection point for the CLK connection to the error detector for the case that two M8046A modules are attached to the M8040A. bugfix Updated selection in export tree when calling ExportResults from toolbar. bugfix Set results selection mode to custom when calling ExportResults from context menu. bugfix Fixed picture for non CMI configuration. bugfix Fixed log message on calibration data instrument mismatch. This message now only contains the relevant instruments. bugfix fixes convolution algorithm. Parts of the kernel were not convolved under specific circumstances. bugfix re-introduce port mapping transform flag, needed for HDMI. bugfix Fixed the report creation date displayed at the top of the page. bugfix Fixed exception when using M8070B AWG interference source while multiple AWGs are connected. bugfix Fix issue with transformed s4p and s6p files. bugfix Script generator threw an exception when M8000 bit pattern did not fulfill granularity but could be rolled out internally by M8070B because the pattern was looped infinitely. bugfix The last letter of an entry in the HTML summary table was sometimes removed. bugfix Fixed: PadIdle macro did not set squelch in M8000 pattern. bugfix Fixed: Export from dynamic connection diagrams did not include details of all duplicated accessories. bugfix Step-by-step instructions for dynamic connection diagrams are not saved in between diagrams. bugfix After disabling step-by-step instructions for dynamic connection diagrams, no elements are grayed-out or hidden. known issue Skew setting is not working for specific low bit rates for Test HF2-51. known issue Waveform Data calculation is not working for HFR2-4. Running HFR2-4 will break saved calculations for HFR2-1 to HFR2-3. known issue HFR7-21 is not working with D9021HDMC HDMI Test App rev. 2.40.2019.0. In order to make it run, you have to enter the following path at the oscilloscope: "C:\ProgramData\Keysight\Infiniium\Apps\HDMIHEACTest\app\config\TransferFunction\CTS21". Now you have to rename all files that start with "WT_HDMI-21_RecepFRLEqu...". Change to "WT_HDMI-21_RFRLEqu...". information The Compliance Mode of this app has been extensively tested. The Expert Mode, however, is not tested to such a great extent and may therefore still contain bugs. information Updated CodeMeter Runtime to version 7.60a to fix vulnerabilities CVE-2021-20093 and CVE-2021-20094. ======================================================================================================================= 1.2 [released 2020-11-23] ======================================================================================================================= 1.2.6.2 [available 2023-09-08] prerequisite Windows 10 (64 bit), English, version 2004 or newer prerequisite Microsoft .NET Framework 4.7.1 or newer prerequisite Keysight IO Libraries Suite 18.1 or newer supported Microsoft Office Excel 2016, English supported D9021HDMC HDMI Test App ver. 2.38.5.0 supported DSAV334A SW rev. 6.60.00403 supported UXR0134A SW rev. 10.25.01302 supported AWG M8195A and M8197A FW rev. 4.1.0.0 bugfix Fixed OutOfMemory Exception by changing the processor architecture from 32 bits to 64 bits. known issue Not fully tested. 1.2.5.1 [available 2022-11-25] prerequisite Windows 10 (64 bit), English, version 2004 or newer prerequisite Microsoft .NET Framework 4.7.1 or newer prerequisite Keysight IO Libraries Suite 18.1 or newer supported Microsoft Office Excel 2016, English supported D9021HDMC HDMI Test App ver. 2.38.5.0 supported DSAV334A SW rev. 6.60.00403 supported UXR0134A SW rev. 10.25.01302 supported AWG M8195A and M8197A FW rev. 4.1.0.0 bugfix FRL EyeWidth and EyeHeight calibration sometimes failed when measuring small eyes. 1.2.4.0 [available 2021-12-13] prerequisite Windows 10 (64 bit), English, version 2004 or newer prerequisite Microsoft .NET Framework 4.7.1 or newer prerequisite Keysight IO Libraries Suite 18.1 or newer supported Microsoft Office Excel 2016, English supported D9021HDMC HDMI Test App ver. 2.38.5.0 supported DSAV334A SW rev. 6.60.00403 supported UXR0134A SW rev. 10.25.01302 supported AWG M8195A and M8197A FW rev. 4.1.0.0 bugfix Running waveform calculation of HFR2-1 to HFR2-4 tests after running HFR2-5 test waveform calculation caused an inconsistency in Compliance mode which is fixed. 1.2.3.0 [available 2021-10-08] prerequisite Windows 10 (64 bit), English, version 2004 or newer prerequisite Microsoft .NET Framework 4.7.1 or newer prerequisite Keysight IO Libraries Suite 18.1 or newer supported Microsoft Office Excel 2016, English supported D9021HDMC HDMI Test App ver. 2.38.5.0 supported DSAV334A SW rev. 6.60.00403 supported UXR0134A SW rev. 10.25.01302 supported AWG M8195A and M8197A FW rev. 4.1.0.0 bugfix Fixed the issue related to the loading and saving of vfp files. 1.2.2.1 [available 2021-09-02] prerequisite Windows 10 (64 bit), English, version 2004 or newer prerequisite Microsoft .NET Framework 4.7.1 or newer prerequisite Keysight IO Libraries Suite 18.1 or newer supported Microsoft Office Excel 2016, English supported D9021HDMC HDMI Test App ver. 2.38.5.0 supported DSAV334A SW rev. 6.60.00403 supported UXR0134A SW rev. 10.25.01302 supported AWG M8195A and M8197A FW rev. 4.1.0.0 bugfix Changes made to the BER estimation procedure algorithm to make sure the required number of bits are sent while testing marginal DUTs. bugfix Warning is not given anymore that scope application version 2.38.5 is not supported. 1.2.1.3 [available 2021-05-21] prerequisite Windows 10 (64 bit), English, version 2004 or newer prerequisite Microsoft .NET Framework 4.7.1 or newer prerequisite Keysight IO Libraries Suite 18.1 or newer supported Microsoft Office Excel 2016, English supported D9021HDMC HDMI Test App ver. 2.38.5.0 supported DSAV334A SW rev. 6.60.00403 supported UXR0134A SW rev. 10.25.01302 supported AWG M8195A and M8197A FW rev. 4.1.0.0 new Option to select the calibrations or tests required in the report. new Support for DSAV334A oscilloscope. new Cable Test ID 5-3 updated based on HDMI_CTS_1.4b_Errata_Test_ID_5-3 from HDMI LA. bugfix The wrong limits had been modified and the termination voltage had been set on the scope application for Cat3 cable tests. bugfix Corrected connection diagram for HDMI TMDS Cable tests. bugfix Cable test 7-1 inconsistencies have been fixed. bugfix TMDS Cable clock test no longer fails when run with N7010 probe. bugfix Selecting 30 bit or 48 bit color depth in Configure DUT threw an exception, which is fixed. modification The FRL waveform calculation is grouped as a different subset and the calibration exclamation mark dependency has been removed from these calculations. known issue TMDS 2.1 data jitter calibrations take more time to finish in UXR than in V-series oscilloscopes. 1.2.0.0 [available 2020-11-23] supported AWG M8195A and M8197A FW rev. 4.0.0.0 supported D9021HDMC HDMI Test App ver. 2.36.2.0 supported UXR0134A SW rev. 10.25.00702 new Support for HDMI Sink gCTS v2.1e new Added support for FRL calibrations on all FRL lanes depending on the data rate. new Added expert mode property to emulate custom S-Parameter file to calibrations and tests where ISI Filter was previously selectable. new Added support for Cat. 3 cable tests. bugfix Added "EnumLegacyValue" attributes to ensure that the new installer works with old vfp files. bugfix Fixed behavior of Keep Signals after test during Sink and Cable tests. bugfix Fixed the Scope App name from N5399C/D to D9021HDMC for TMDS Jitter Calibration property. bugfix Fixed no FRL waveform generated when running eye width calibration if the previous calibration failed at step 0. bugfix Fixed table names for HDMI FRL sink test procedures. bugfix Fixed critical error when loading project file. bugfix Fixed issue that FRL eye width calibration aborted with 0 value. known issue Wrong TPA shown for Cable tests. Use TPA-R instead of TPA-P on AWG side. ======================================================================================================================= 1.1 [released 2020-04-30] ======================================================================================================================= 1.1.3 [available 2020-06-30] tested with AWG M8195A and M8197A FW rev. 4.0.0.0 tested with D9021HDMC HDMI Test App ver. 2.35.0.0 tested with DSAV334A SW rev. 6.40.01201 tested with UXR0134A SW rev. 10.12.05302 bugfix Fixed user decision popup issues with ValiFrameRemote. bugfix Fixed InvalidProgramException issues due to encryption in ValiFrameRemote. 1.1.2 [available 2020-06-25] tested with AWG M8195A and M8197A FW rev. 4.0.0.0 tested with D9021HDMC HDMI Test App ver. 2.35.0.0 tested with DSAV334A SW rev. 6.40.01201 tested with UXR0134A SW rev. 10.12.05302 bugfix Fixed licensing issues with ValiFrameRemote. 1.1.1 [available 2020-05-29] tested with AWG M8195A and M8197A FW rev. 4.0.0.0 tested with D9021HDMC HDMI Test App ver. 2.35.0.0 tested with DSAV334A SW rev. 6.40.01201 tested with UXR0134A SW rev. 10.12.05302 bugfix Fixed issue with exporting FRL Differential Swing Tolerance Test results. 1.1.0 [available 2020-04-30] tested with AWG M8195A and M8197A FW rev. 4.0.0.0 tested with D9021HDMC HDMI Test App ver. 2.35.0.0 tested with DSAV334A SW rev. 6.40.01201 tested with UXR0134A SW rev. 10.12.05302 new Added support for UXR known issue TMDS jitter calibration requires frequent restart of UXR firmware. known issue Cable inter-pair test not working with UXR. known issue 2.1 TMDS jitter calibrations fail when started directly after 1.4 TMDS jitter calibrations. Restarting 2.1 TMDS jitter calibrations solves the issue. bugfix Fixed termination voltage issues with HF jitter calibrations. ======================================================================================================================= 1.0 [released 2020-04-29] ======================================================================================================================= 1.0.0 [available 2020-04-29] tested with AWG M8195A and M8197A FW rev. 4.0.0.0 tested with D9021HDMC HDMI Test App ver. 2.33.0.0 tested with DSAV334A SW rev. 6.40.01201 new Uses BLM (BitifEye License Manager) licensing. new Requires installation of BitifEye HDMI PHY IPAuxiliary files. new Configurations with M8190A, ParBERT system and Bias-T option with M8195A are not supported. new Support for HDMI gCTS v2.1b. new First ValiFrame HDMI PHY N5991 product release.