===== N5991 SATA Test Automation ===== ======================================================================================================================= 1.2 [released 2023-06-30] ======================================================================================================================= 1.2.0.2 [available 2023-06-30] prerequisite Windows 10 (64 bit), English, version 1809 or newer prerequisite Microsoft .NET Framework 4.8 or newer prerequisite Keysight IO Libraries Suite 18.1 or newer supported Microsoft Office Excel 2016, English supported M8070B 9.5 Release (9.5.250.2) supported Infiniium 06.73.00102 supported Infiniium UXR 11.50.00401 new UXR-B support. modification Changed the transfer function path on the oscilloscope from "C:\Filters" to "C:\Users\Public\Documents\Infiniium\Filters\SATA". modification Transfer functions are now sent automatically to the oscilloscope. To use custom transfer functions they must be stored in the local settings path "C:\ProgramData\BitifEye\ValiFrameK1\SATA\Settings\". Existing transfer functions with the same name in the subfolder of "C:\Users\Public\Documents\Infiniium\Filters\SATA" on the oscilloscope will be overwritten. ======================================================================================================================= 1.1 [released 2023-01-31] ======================================================================================================================= 1.1.0.5 [available 2023-01-31] prerequisite Windows 10 (64 bit), English, version 1809 or newer prerequisite Microsoft .NET Framework 4.8 or newer prerequisite Keysight IO Libraries Suite 18.1 or newer supported Microsoft Office Excel 2016, English supported M8070B 9.5 Release (9.5.250.2) supported Infiniium 06.73.00102 supported Infiniium UXR 11.40.00105 new Added a button in the About Dialog to directly navigate to the API documentation. new It is now possible to export the log file from the context menu of the log window in the main window of ValiFrame K1. The functionality to export the log file is also accessible from the remote API. new License Certified Time will be updated automatically at the start-up of ValiFrame. new Exporting results is now possible from any node in the ValiFrame sequence tree using the context menu. new The results of procedures now show a compliance mode indicator. This indicator also takes into account the compliance state of all relevant calibrations. Procedures that run offline are considered not compliant. new Nodes in the sequence tree in ValiFrame are now selectable and deselectable by pressing the spacebar. new Improved visibility of warnings and critical errors. The number of warnings and critical errors is now displayed: - as additional log entries at the end of each run, - in the run end window and - in the status bar. modification Changed step size in the jitter tolerance tests for the low result confidence to improve test time. modification Removed not needed Math function on the oscilloscope for RJ and SJ calibration. modification Changed default values for Rcvr SSC Tolerance tests to improve test time. modification Only test results are saved in vfp files. Calibration results are not saved. modification Added standalone tool to transform a ValiFrame log into a JSON file. modification Introduced a new logging level called "Context" which is used to log context start/end into the log file. It is not visible in the UI. modification Improved Logging using the Iso format for the date and added tabs as dividers. modification The auto-generated documentation for the ValiFrame remote API is now included in the installer. Also a start menu shortcut to it is generated. modification Cached maximum instrument bandwidth to avoid unnecessary SCPI queries. modification Make loading of M8000 states more robust. modification Removed ValiFrameRemoteGui and all C# example code from the installers. modification Improved EZJIT parsing. Unrecognized tokens will be output as a log warning. modification Added tooltip hint for maintenance status label. modification Installers now check (by looking at the available licenses) if installing the product would push a product or feature past maintenance end. If yes, a warning is presented to the user. modification Disabled the option to close the results view of an ongoing test run. modification Warning messages in StationConfigurator "Check Connections" turn the matching instrument line yellow. modification Improved formatting of summary table in exported HTML results. Entries in the result column are now color coded. modification HTML reports are now generated as a single file. Styles, scripts and images are embedded in that file. modification UI changes of helper window explaining the meaning of sequencer icons. Context menu entry is now called "Show State Details..." bugfix Disabled the CDR for synchronization of the error detector. bugfix A full auto alignment is done on each procedure initialization to ensure the best sampling point. bugfix Set results selection mode to custom when calling ExportResults from context menu. bugfix Fixed the connection point for the CLK connection to the error detector for the case that two M8046A modules are attached to the M8040A. bugfix Fixed duplicated 'Transfer Functions' folder name when applying transfer function. bugfix Fixed connection diagram button displayed incorrectly on certain screens. bugfix Fixed spelling in connection diagram dialog. bugfix The "Unreleased Software" banner has been moved to the right of the window and made less wide. The main window of ValiFrame has now a minimum size of 600x600. These changes were done so that the banner is not overlapping other controls when the window is shrunk. bugfix Fixed an issue that prevented the gathering of all available relevant data in case of a crash. bugfix Fixed wrong assignment of parameter value in VFCalTable. bugfix Fixed. On attempting to install ValiFrame while the software was running, an incorrect message was displayed about which software was already running. bugfix Fixed exception when exporting to Excel. bugfix Fixed instrument selection in the StationConfigurator. bugfix The ValiFrame main window did not close properly when report subwindows were open. bugfix The OK button in the critical error window was unreachable due to incorrect scaling on high DPI machines. bugfix Sheets in exported result workbooks were in the wrong order if the target format was an Excel file. bugfix Expiration dates for demo licenses were not displayed in the ValiFrame About window and in the logfile. bugfix When a calibration procedure failed or was aborted, calibration table properties and values could be corrupted for the rest of the program runtime. Restarting ValiFrame restored the correct values. bugfix Bundled licenses were not shown in the ValiFrame About window. known issue For some DUTs, loopback training gets stuck, which is indicated by the M8070B GUI showing a blue BER icon with the text "Acquiring Data" as well as a "BUSY" indicator at the bottom of the GUI. Workaround: To continue the test a power cycle on the DUT is needed. information Updated CodeMeter Runtime to version 7.51. ======================================================================================================================= 1.0 [released 2021-04-22] ======================================================================================================================= 1.0.5.1 [available 2022-09-15] prerequisite Windows 10 (64 bit), English, version 2004 or newer prerequisite Microsoft .NET Framework 4.7.1 or newer prerequisite Keysight IO Libraries Suite 18.1 or newer supported Microsoft Office Excel 2016, English supported M8070B 7.5 Release (7.5.700.8) supported Infiniium 6.60.00403 supported Infiniium UXR 10.25.01302 bugfix U Host Differential Voltage Calibrations with UXR Junior threw "data out of range" exception. known issue The instrument summary table in the workbook export lists the instruments that were connected during the export. If the instruments have changed in any way since the last run, this may result in incorrect information being listed in the instrument summary table. 1.0.4.0 [available 2021-12-23] prerequisite Windows 10 (64 bit), English, version 2004 or newer prerequisite Microsoft .NET Framework 4.7.1 or newer prerequisite Keysight IO Libraries Suite 18.1 or newer supported Microsoft Office Excel 2016, English supported M8070B 7.5 Release (7.5.700.8) supported Infiniium 6.60.00403 supported Infiniium UXR 10.25.01302 bugfix Necessary html template files were not installed known issue The instrument summary table in the workbook export lists the instruments that were connected during the export. If the instruments have changed in any way since the last run, this may result in incorrect information being listed in the instrument summary table. 1.0.3.3 [available 2021-10-01] prerequisite Windows 10 (64 bit), English, version 2004 or newer prerequisite Microsoft .NET Framework 4.7.1 or newer prerequisite Keysight IO Libraries Suite 18.1 or newer supported Microsoft Office Excel 2016, English supported M8070B 7.5 Release (7.5.700.8) supported Infiniium 6.60.00403 supported Infiniium UXR 10.25.01302 modification Support for UTD 1.6 is shown modification Updated codemeter runtime known issue The instrument summary table in the workbook export lists the instruments that were connected during the export. If the instruments have changed in any way since the last run, this may result in incorrect information being listed in the instrument summary table. 1.0.2.0 [available 2021-05-21] prerequisite Windows 10 (64 bit), English, version 2004 or newer prerequisite Microsoft .NET Framework 4.7.1 or newer prerequisite Keysight IO Libraries Suite 18.1 or newer supported Microsoft Office Excel 2016, English supported M8070B 7.5 Release (7.5.700.8) supported Infiniium 6.60.00403 supported Infiniium UXR 10.25.01302 bugfix Properties of SJ calibration missing in calibration file known issue The instrument summary table in the workbook export lists the instruments that were connected during the export. If the instruments have changed in any way since the last run, this may result in incorrect information being listed in the instrument summary table. 1.0.1.0 [available 2021-05-11] prerequisite Windows 10 (64 bit), English, version 2004 or newer prerequisite Microsoft .NET Framework 4.7.1 or newer prerequisite Keysight IO Libraries Suite 18.1 or newer supported Microsoft Office Excel 2016, English supported M8070B 7.5 Release (7.5.700.8) supported Infiniium 6.60.00403 supported Infiniium UXR 10.25.01302 bugfix Exporting workbook when Excel is not installed known issue The instrument summary table in the workbook export lists the instruments that were connected during the export. If the instruments have changed in any way since the last run, this may result in incorrect information being listed in the instrument summary table. 1.0.0.14 [available 2021-04-22] supported M8070B 7.5 Release (7.5.700.8) supported Infiniium 6.60.00403 supported Infiniium UXR 10.25.01302 new Support for M8040A new Support for UXR Scopes known issue The instrument summary table in the workbook export lists the instruments that were connected during the export. If the instruments have changed in any way since the last run, this may result in incorrect information being listed in the instrument summary table.