N5990A Software Packages

COMPUTER BUS STANDARDS

MOBILE DEVICE AND MEMORY STANDARDS
PCIe GEN 4 & below
N5990A-010 | Test Sequencer |
N5990A-005 | Integrated BER Counter Interface Support |
N5990A-008 | Remote Power Management Support |
N5990A-101 | PCI Express Receiver Tests |
N5990A-111 | PCI Express u.2 Receiver Test Add-On |
N5990A-301 | PCI Express Link Training Suite |
N5990A-501 | PCI Express Link Equalization Tests |
N5990A-011 | Upgrade to current PCIe CTS Standard and Test Instrument Support (for 101, 111, 501) |
N5990A-031 | Upgrade to PCI Express Link Training Suite (for 301) |
N5990A-004 | Switch System and DSGA Platform Support |
N5990A-601 | N5990A One Year Software Maintenance Extension PCIe |
N5990A-010 | Test Sequencer |
N5990A-005 | Integrated BER Counter Interface Support |
N5990A-008 | Remote Power Management Support |
N5990A-103 | SATA RSG Tests |
N5990A-303 | SATA Link Training Suite |
N5990A-013 | Upgrade to current SATA U.T.D.-Standard and Test Instrument Support (for 103) |
N5990A-603 | N5990A One Year Software Maintenance Extension SATA |
N5990A-010 | Test Sequencer |
N5990A-005 | Integrated BER Counter Interface Support |
N5990A-006 | Type-C, Alt Mode Receiver Tests and PDO Support |
N5990A-008 | Remote Power Management Support |
N5990A-102 | USB Receiver Tests |
N5990A-302 | USB Link Training Suite |
N5990A-012 | Upgrade to current USB CTS and Test Instrument Support (for 102) |
N5990A-032 | Upgrade to USB Link Training Suite (for 302) |
N5990A-602 | N5990A One Year Software Maintenance Extension USB |
N5990A-010 | Test Sequencer |
N5990A-005 | Integrated BER Counter Interface Support |
N5990A-006 | Type-C, Alt Mode Receiver Tests and PDO Support |
N5990A-104 | Thunderbolt Receiver Tests |
N5990A-020 | Upgrade to current Thunderbolt Test Specification Standard and Test Instrument Support |
N5990A-604 | N5990A One Year Software Maintenance Extension TBT |
N5990A-010 | Test Sequencer |
M8085CC1A-1NP | MIPI C-PHY 1.2 Calibration, Conformance and Characterization Procedures for M819xA AWG, Network/Floating, Perpetual License |
M8085CC1A-1TP | MIPI C-PHY 1.2 Calibration, Conformance and Characterization Procedures for M819xA AWG, Transportable, Perpetual License |
M8085CE1A-1NP | MIPI C-PHY 1.2 Editor for M819xA AWG, Network/Floating, Perpetual License |
M8085CE1A-1TP | MIPI C-PHY 1.2 Editor for M819xA AWG, Transportable, Perpetual License |
M8085CUEA-1TP | Upgrade C-PHY Editor from M8085A-CT1 to C-PHY 1.2, Transportable, Perpetual License |
M8085CUEA-1NP | Upgrade C-PHY Editor from M8085A-CN1 to C-PHY 1.2, Network/Floating, Perpetual License |
M8085CUCA-1TP | Upgrade C-PHY Editor plus Calibration, Conformance and Characterization Procedures from M8085A-CT1 and M8085A-CTA to C-PHY 1.2, Transportable, Perpetual License |
M8085CUCA-1NP | Upgrade C-PHY Editor plus Calibration, Conformance and Characterization Procedures from M8085A-CN1 and M8085A-CNA to C-PHY 1.2, Network/Floating, Perpetual License |
N5990A-010 | Test Sequencer |
N5990A-005 | Integrated BER Counter Interface Support |
M8085DE1A-1TP | MIPI D-PHY 2.0 Editor for M819xA AWG, Transportable, Perpetual License |
M8085DE1A-1NP | MIPI D-PHY 2.0 Editor for M819xA AWG, Network/Floating, Perpetual License |
M8085DC1A-1TP | MIPI D-PHY 2.0 Calibration, Conformance and Characterization Procedures for M819xA AWG, transportable, perpetual License |
M8085DC1A-1NP | MIPI D-PHY 2.0 Calibration, Conformance and Characterization Procedures for M819xA AWG, Network/Floating, Perpetual License |
M8085DUEA-1TP | Upgrade D-PHY Editor from M8085A-DT1 to D-PHY 2.0, Transportable, Perpetual License |
M8085DUEA-1NP |
Upgrade D-PHY Editor from M8085A-DN1 to D-PHY 2.0, Network/Floating, Perpetual License |
M8085DUCA-1TP | Upgrade D-PHY Editor plus Calibration, Conformance and Characterization Procedures from M8085A-DT1 and M8085A-DTA to D-PHY 2.0, Transportable, Perpetual License |
M8085DUCA-1NP |
Upgrade D-PHY Editor plus Calibration, Conformance and Characterization Procedures from M8085A-DN1 and M8085A-DNA to D-PHY 2.0, Network/Floating, Perpetual License |
N5990A-010 | Test Sequencer |
N5990A-004 | Switch System and DSGA Platform Support |
N5990A-165 | MIPI M-PHY Receiver Tests |
N5990A-167 | UFS/UniPro Rx Physical Conformance Test Matrix |
N5990A-366 | MIPI M-PHY Frame Generator |
N5990A-367 | MIPI M-PHY/Unipro Error Counter and Test Script Wizard |
N5990A-018 | Upgrade to MIPI M-PHY Compliance Test Specification Standard and and Test Instrument Support (for 165, 167) |
N5990A-665 | N5990A One Year Software Maintenance Extension MIPI M-PHY |

AUDIO / VIDEO BUS STANDARDS
N5990A-010 | Test Sequencer |
N5990A-005 | Integrated BER Counter Interface Support |
N5990A-151 | HDMI Sink Tests |
BIT-2010-0005-0 | HDMI Frame Generator |
N5990A-014 | Upgrade to current HDMI Compliance Test Specification Standard (for 151) |
N5990A-650 | N5990A One Year Software Maintenance Extension HDMI |
BIT-2010-0009-0 | HDMI PHY Debug Tools SCDC controller GUI Support |
N5990A-010 | Test Sequencer |
N5990A-004 | Switch System and DSGA Platform Support |
N5990A-005 | Integrated BER Counter Interface Support |
N5990A-006 | Type-C, Alt Mode Receiver Tests and PDO Support |
N5990A-155 | DisplayPort Receiver Tests |
N5990A-156 | eDP Receiver Tests Add-On |
N5990A-015 | Upgrade to current DP Compliance Test Specification standard and Test Instrument Support (for opt. 156, 156) |
N5990A-655 | N5990AOne Year Software Maintenance Extension DP |
OVERVIEW SOFTWARE MAINTENANCE AND UPGRADES (discontinued)
One Year Software Maintenance Extension Lic. Sheet covers on-going product enhancements up until July 30th 2022. After this date no enhancements will be made anymore. The SWM extensions will be available directly from BitifEye, but limited to July 30th 2022.
First year is included in N5990A core product (Opt. 010) and N5990A upgrade options (e.g. Opt. 011), which include minor CTS updates. Major CTS updates (e.g. from PCIe Gen3 to Gen4 ) are excluded and require N5990A upgrade options. It is available for each supported standard.
N5990A-601 N5990A One Year Software Maintenance Extension PCI Express
N5990A-602 N5990A One Year Software Maintenance Extension USB
N5990A-603 N5990A One Year Software Maintenance Extension SATA
N5990A-604 N5990A One Year Software Maintenance Extension TBT
N5990A-605 N5990A One Year Software Maintenance Extension SAS
N5990A-650 N5990A One Year Software Maintenance Extension HDMI
N5990A-655 N5990A One Year Software Maintenance Extension DisplayPort
N5990A-665 N5990A One Year Software Maintenance Extension MIPI M-PHY
One Year Software Maintenance Extension Lic. Sheet covers on-going product enhancements until July 30th 2021. After this date no enhancements will be made anymore.
First year is included in N5990A core product (Opt. 010) and N5990A upgrade options (e.g. Opt. 011), which include minor CTS updates. Major CTS updates (e.g. from PCIe Gen3 to Gen4 ) are excluded and require N5990A upgrade options. It is available for each supported standard.
Option 011: Upgrade from PCIe Gen 3 to Gen 4 Compliance Test Specification Standard
Option 012: Upgrade from USB 3.0/3.1 Gen1 to USB 3.1 Gen2 Compliance Test Specification Standard
Option 013: Upgrade to current Serial ATA Unified Test Document Standard
Option 014: Upgrade from HDMI 1.4 to 2.0 Compliance Test Specification Standard
Option 015: Upgrade from DP 1.2 to 1.4 Compliance Test Specification Standard
Option 018: Upgrade from MIPI M-PHY Gear 3 to Gear 4 Conformance Test Suite Standard
Option 019: Upgrade to current SD UHS-II Test Specification Standard and Test Instrument Support
Option 020: Upgrade to uneven datarate Thunderbolt Tests Speeds
Option 031: Upgrade from PCI Express Gen 3 to Gen 4 Link Training Suite
Option 032: Upgrade from USB 3.0/3.1 Gen1 to USB 3.1 Gen2 Link Training Suite
Option 033: Upgrade from MIPI M-PHY Gear 3 to Gear 4 Frame Generator Software
BASE OPTIONS (discontinued)
Contains GUI, Report Generation, Remote Interface and 1 yr S/W Maintenance. Is needed to run all flavors of ValiFrame Test Automation Software (Options 100 – 199). Can be added to M8085A, when a Test Sequencer function is required.
Also this option provides the possibility to programmatically control ValiFrame from another program through the ValiFrameRemote interface. If you are looking to include custom calibration and test procedures as well as instrument drivers, this function is provided with N5990-500 User Programming
Allows to integrate BitifEye´s 2100 Switch System and BIT-3000 DSGA into Valiframe.
Use programmable switches to test multiple lanes without manual re-connections. This can significantly reduce test times and required user interaction. This option is only required once per test station, not once per standard.
Not all standards support this option, so please contact BitifEye.
It is only needed for receiver / sink test set ups and for N5990A-006.
For some DUTs proprietary tools exist to control the device (e.g. set it to loopback mode) as well as for reading internal checksum error counters, burst counters, or other indicators. These indicators make it possible to determine whether the receiver was able to receive the data properly. The integration of such proprietary tools into the Test Automation Software can be achieved with the iBerReader software interface. The interface acts as a wrapper for such tools and the definition is given in C# .NET. It follows the interface defined in the different MIPI PHY CTSs (e.g. for M-PHY: Appendix H – Standardized Software Interface for Test Automation), Computer Bus CTSs, or HDMI CTS.
N5990A-006 provides full control of the USB Type-C interface which is core to the RX and TX compliance testing in USB 3.1, Thunderbolt and DisplayPort in their own ALT-Modes as well power contracts (consuming or providing) can be made up to 100 Watts. Test results are available as HTML or Excel workbook. It can be combined to N5990A-102 (USB). – 104 (Thunderbolt) and -155 (DisplayPort).
It is required to power-cycle the DUT several times at certain moments during the receiver tests. This means that the N5990A user needs to sit in front of the controller PC and wait until he is asked by the test automation to power-cycle the DUT. Not only is this task time-consuming, it is error prone. If the user forgets to or does not power-up the DUT properly, the current test will need to be repeated. With N5990A Option -008 or Remote Power Management Support, the number of user interactions and thus the room for errors and potential delays are minimized.
With N5990A Option -008, the user only has to make sure that the DUT is properly connected to a PDU (power distribution unit) or a Keysight power supply once during the very first receiver test and let the test automation power-cycle the DUT when required.
Suppoted PDUs are Koukaam NetIO-230B, Koukaam NetIO-230C, Allnet ALL 4076, Synaccess NP (USA connectors) Keysight Power Supplies (only used with USB tests): E3631A, E363xA, E364xA,N67xx