======================================================================================================================= 4.21 [released 2023-05-15] ======================================================================================================================= 4.21.3 [available 2023-05-15] prerequisite Windows 10 (64 bit), English, version 1809 or newer prerequisite Microsoft .NET Framework 4.8 or newer prerequisite Keysight IO Libraries Suite 18.1 or newer supported UXR Infiniium 11.30.00406 supported Infiniium 6.73.00102 supported D9040MPHC 02.60.0005 supported M8070B 9.5.510.10 supported DSGA FW 1.20 and System 1.11 supported Microsoft Office Excel 2016, English modification Relaxed the SYNC_Length value to max 32768 in case SYNC_range value is FINE. modification Modified to automatically push a transfer function file to target directory at Oscilloscope. modification Applied the configuration of DataLane to the Tx ScopeApp. modification Workaround for (HF)SJ calibrations in the presence of a channel embedded in a non-UXR scope in Gear1. bugfix Fixed the Crest Factor for RJ at target BER 1E−12. bugfix Fixed the critical error in Eye Opening calibration regarding missing transition in histogram measurements. bugfix Fixed the Low Pass Filter setting in RJ calibrations for Gear2. bugfix Fixed the Pass/Fail criteria for Squelch tests 2.4.5 and 2.4.6. bugfix Fixed the issue of Setup procedure; The Unipro sequence is selected in accordance to the selected HS-Gear. known issue Offline and Custom BER reader do not work with DSGA in the setup. known issue The (HF)SJ calibrations in Gear1 are slow whenever a non-UXR scope is used and a transfer function file is embedded. known issue In Remote procedure call, the Excel module may fail during export of the workbook, please try to export again. known issue In the "About" dialog, the ValiFrame version is shown as 4.213 but actually it is 4.21.3. information The 'UFS Clock Test Setup' part in D9040MPHC 02.60.0005 is not supported in Tx Test 4.20.8 [available 2021-05-07] supported UXR Infiniium 10.25.00702 supported Infiniium 06.55.00702 supported D9040MPHC 02.40.0.0 supported M8070B 7.2.40.2 supported DSGA FW 1.20 and System 1.11 supported Excel 2016 modification Changed the format of Test Report in Excel as version 4.20.4 known issue Offline and Custom BER reader don’t work with DSGA in the setup known issue Distortions in Eye Diagram happen when embedding package to Scope known issue In Remote procedure call, the Excel module may fail during export workbook, please try to export again known issue In the "About" dialog, ValiFrame version shows 4.208 but actually it is 4.20.8 information The 'UFS Clock Test Setup' part in D9040MPHC 02.40.0.0 is not supported in Tx Test 4.20.7 [available 2021-05-05] supported UXR Infiniium 10.25.00702 supported Infiniium 06.55.00702 supported D9040MPHC 02.40.0.0 supported M8070B 7.2.40.2 supported DSGA FW 1.20 and System 1.11 supported Excel 2016 bugfix Fixed the screenshot of the Tx tests 1.1.6 and 1.1.7 covers some of info in the report bugfix Fixed the issue when multiple setup procedures are run, an Excel report workbook cannot be created known issue Offline and Custom BER reader don’t work with DSGA in the setup known issue Distortions in Eye Diagram happen when embedding package to Scope known issue In Remote procedure call, the Excel module may fail during export workbook, please try to export again known issue In the "About" dialog, ValiFrame version shows 4.207 but actually it is 4.20.7 information The 'UFS Clock Test Setup' part in D9040MPHC 02.40.0.0 is not supported in Tx Test 4.20.4 [available 2021-04-08] bugfix Fixed the TableData parameters of ScopeApp not part of test report bugfix Fixed the Tx Setup procedure throws error when exporting the result workbook in Excel 4.20.1 [available 2020-09-28] information Updated CodeMeter Runtime to version 7.10a to fix vulnerabilities CVE-2020-14513, CVE-2020-14519, CVE-2020-14509, CVE-2020-14517, CVE-2020-16233, and CVE-2020-14515 known issue In the "About" dialog, ValiFrame version shows 4.201 but actually it is 4.20.1 4.20.0 [available 2020-09-23] new Support 33ps TTCs for G4 instead of 60ps TTCs new Recalculate target ISI for G3 and G4 for Embedded Fixture ISI Calibration new Add Sigtest equalization information to log and report tested with UXR Infiniium 10.25.00702 tested with Infiniium 06.55.00702 tested with D9040MPHC 02.40.0.0 tested with M8070B 7.2.40.2 tested with DSGA FW 1.20 and System 1.11 tested with Excel 2016 bugfix Fixed the equalization setting for tests 1.1.7 G3 set as CTS bugfix Fixed the pass conditions of tests 2.4.5 and 2.4.6 bugfix Fixed the ScopeApp connection diagram when called via ValiFrameRemote bugfix Fixed the DataLane index in the connection diagram modification Changed properties related to Transfer Function File for Test 1.1.7 modification Changed name of several TX tests to match name in D9040MPHC known issue Offline and Custom BER reader don’t work with DSGA in the setup known issue Distortions in Eye Diagram happen when embedding package to Scope known issue In the "About" dialog, ValiFrame version shows 4.200 but actually it is 4.20.0 ======================================================================================================================= 4.0 [released 2020-02-18] ======================================================================================================================= 4.0.7 [available 2020-04-09] bugfix TX Setup Procedure no longer enables M8020A data outputs when DSGA and UniPro BER Reader is used 4.0.6 [available 2020-03-16] bugfix DIFZ macro 4.0.5 [available 2020-02-18] new Property to disable usage of TTCs (against CTS!!) new Use BLM Protection new Folder structure (ValiFrameK0) new UXR Junior support tested with Infiinium UXR 10.11.04711 tested with Infiinium 06.40.01101 tested with D9040MPHC 02.30.0002 tested with M8070B 6.5.550.2 tested with DSGA FW 1.20 and System 1.11 tested with Excel 2016 modification DIFZ macro disabled due to known issue modification 3 and 4 lane configuration only tested with Offline M8070B modification Adjusted the jitter calibrations transition count property bugfix Calibration range for some jitter calibrations bugfix Loading vfp files now properly restores which procedures were selected in the sequence tree bugfix Squelch Tests bugfix ISI custom and automatic presets bugfix Excel related issues bugfix Fixed Oscilloscope Bandwidth property known issue Result of ISI calibration is only updated in property grid of other procedures when the configuration is reloaded or the procedure is executed known issue Excel can crash when report is modified while ValiFrame populates it 4.04.03 [2019-08-20]: bugfix Some Setup Procedures for TX were using the wrong link configuration sequence 4.04.02 [2019-08-09]: modification Allow change of acquisition settings in SigTest Eye Opening calibrations in Compliance Mode modification Tested with M8070B 6.0.210.6 modification Tested with Infiniium 06.40.01001 modification Tested with U7249E 2.20.0000 bugfix Fixed channel reported in L2L Skew test 4.04.01 [2019-07-31]: new Fix steps for 2.1.1/3 in Compliance Mode (it was running as Expert) 4.04.00 [2019-07-23]: new Support M8070B new Add DIFZ support new Feature added to select between solid state and relay switches new Support solid state switch in DSGA new Include the Tabledata of scopeapp report in Valiframe report so that both are consistent 4.01.00 [2017-10-02]: new Support testing all lanes simultaneously or separately with UniPro PHY Test Mode new Support HS-Gear 4