======================================================================================================================= 2.60 [released 2021-04-06] ======================================================================================================================= 2.60.2.0 [available 2021-05-21] prerequisite Windows 10 (64 bit), English, version 2004 or newer prerequisite Microsoft .NET Framework 4.7.1 or newer prerequisite Keysight IO Libraries Suite 18.1 or newer supported Microsoft Office Excel 2016, English supported M8070B 7.5 Release (7.5.700.8) supported Infiniium 6.60.00403 bugfix Properties of SJ calibration missing in calibration file known issue The instrument summary table in the workbook export lists the instruments that were connected during the export. If the instruments have changed in any way since the last run, this may result in incorrect information being listed in the instrument summary table. 2.60.1.0 [available 2021-05-11] prerequisite Windows 10 (64 bit), English, version 2004 or newer prerequisite Microsoft .NET Framework 4.7.1 or newer prerequisite Keysight IO Libraries Suite 18.1 or newer supported Microsoft Office Excel 2016, English supported M8070B 7.5 Release (7.5.700.8) supported Infiniium 6.60.00403 bugfix Exporting workbook when Excel is not installed known issue The instrument summary table in the workbook export lists the instruments that were connected during the export. If the instruments have changed in any way since the last run, this may result in incorrect information being listed in the instrument summary table. 2.60.0.8 [available 2021-04-06] supported M8070B 7.5 Release (7.5.700.8) supported Infiniium 6.60.00403 known issue The instrument summary table in the workbook export lists the instruments that were connected during the export. If the instruments have changed in any way since the last run, this may result in incorrect information being listed in the instrument summary table. ======================================================================================================================= 2.5 [released 2020-04-29] ======================================================================================================================= 2.51 [available 2020-09-28] information Updated CodeMeter Runtime to version 7.10a to fix vulnerabilities CVE-2020-14513, CVE-2020-14519, CVE-2020-14509, CVE-2020-14517, CVE-2020-16233, and CVE-2020-14515 2.50 [available 2020-04-29] tested with M8070B FW rev: 7.0.600.4 tested with Infiinium FW rev. 6.55.00401 new Remove N4903B J-BERT new Migration to BLM license system known issue Connection diagrams do not reflect special expert mode selections 2.40 [2019-08-31]: tested with DSO FW 6.20.01101 tested with J-BERT N4903B FW rev. 7.64 tested with J-BERT M8070A FW rev. 5.0.222.2 modification Force the RJ Low Pass Filter frequency to be 100MHz for Gen1 & Gen2 bugfix Fixes in AutoScaleSource function new Add Internal ISI Feature 2.31 [2018-08-31]: tested with DSO FW 6.20.01101 tested with J-BERT N4903B FW rev. 7.64 tested with J-BERT M8070A FW rev. 5.0.222.2 tested with Tx App (N5411): tested version is 1.86 modification Several minor improvements, mostly GUI related bugfix Several minor bugfixes 2.30 [2017-01-20]: modification Tested with DSO FW 5.75.00218 modification Tested with J-BERT N4903B FW rev. 7.64 modification Tested with J-BERT M8070A FW rev. 3.1.55.14 modification Supports N5411B SATA Tx Test Application versions 1.71 (Windows XP) and 1.84 (Windows 7) modification Supports SerialTek BusXpert version 4.0.1017 new Added single channel electrical idle for M8020A. Details: Combined selection of Rx and Tx BIST modes in the StationConfigurator into a common UI element. Removed option 'Manual With Data Generator'. Added checkbox 'Use channel add for electrical idle'. De-emphasis settings in the Connfigure DUT dialog are not available for N4903 with 'Use channel add' enabled. modification Allow up to 16 ALIGN primitives per block instead of only 4. This change is not available in legacy mode, the limit is still 4 there. modification Set skew to 0 and disable external scaling for all channels before starting any scope app test. modification Replaced 'Skip Instrument Re-Initialization' property with 'Skip Instrument Reset' property. It is now possible to completely skip the instrument initialization even on the first run. modification Added more progress logging to receiver tests. modification Updated description for the 'BIST Mode Selection' property. modification Added padding pattern data before and after bursts to compensate for M8020A idle feature inaccuracy. modification Adjusted default sequence to avoid issues with M8000 macros not falling on the internal granularity borders in a block. modification When a clock loss is detected on the N4903B before an align attempt, reset the fine adjust value to 0. There are cases where a clock loss can be fixed by that. There are no cases where resetting the fine adjust can make things worse if we already have a clock loss. modification Made TX tests respect the 'Abort' button. modification Automatically break out of TX tests when an event is received that would lead to an endless loop otherwise. bugfix Fixed incorrect TJ spec limit for u hosts. bugfix Fixed a bug where M8000 trigger out was enabled in some cases where it was not needed. bugfix Fixed a bug where BIST activation was not correctly working in legacy mode for TX tests. bugfix Fixed a bug where the N4903 sequence size limits where violated in Rx Gen2 host tests with trigger. Details: Only append the full Tx pattern sequence in legacy mode, each pattern only once otherwise. 2.25 [2015-12-08]: modification Tested with DSO FW 4.20.0017 (Windows XP) and FW 5.51.0002 (Windows 7) modification Tested with J-BERT N4903B FW rev. 7.61 modification Tested with J-BERT M8070A FW rev. 2.6.4.6 modification Supports N5411B SATA Tx Test Application versions 1.71 (Windows XP) and 1.82 (Windows 7) modification Supports SerialTek BusXpert version 4.0.960 new Added 'Skip Instrument Re-Initialization' feature. new Optimized DVD Framework initialization code to avoid unnecessary reinitializations in repeated runs. new Made power cycling before loopback training optional. Details: Replaced property 'AlwaysPowerCycle' with 'PowerCycleMode'. PowerCycleMode = Always is equivalent to AlwaysPowerCycle = true, PowerCycleMode = OnlyOnRetry is equivalent to AlwaysPowerCycle = false, PowerCycleMode = Never is the new option introduced with this change. new Scope app (N5411B): Added new test TSG-17. new Scope app (N5411B): Added support for M8020A. new Scope app (N5411B): Added company selection to Station Configurator to switch between Keysight and Agilent versions. modification Changed BIST automation for TX tests to use real BIST-T instead of faking it with BIST-L and sending in the requested patterns. modification Removed Gen1&2 cal and RX test procedures for interface u. (Those are defined in the spec, but not the UTD; we also did not do them correctly anyway and just used interface i instead.) modification Power cycle the DUT when a scope app OOB test requests to make sure the DUT is in neither BIST-L nor BIST-T for the first time in a test run. modification Legacy mode: Make sequence import fail if the J-BERT is set to Second Channel mode. That will make it harder to import sequences created with the Link Training Suite, which would not work in legacy mode. modification Made the '# aligns' property affect the whole training sequence again, instead of only the payload. modification Changed the property 'Jitter step size' in Random Jitter Cal so it applies to set jitter, not measured jitter. modification Changed the way jitter is set up for M8020A to make sure the jitter sources are always phase aligned. modification Always display blocking capacitors on both tx outputs, but mark and describe them as optional. modification Replaced several connection diagram elements that were drawings before with images of the real hardware. modification Adjusted sizes of instrument pictures in the Station Configurator to more closely resemble the real world relative sizes of the instruments. bugfix Fixed issues with trigger line display for TX tests. bugfix Fixed a bug where the same connection diagram was shown twice for triggered host TX tests. bugfix Fixed a bug where in some configurations a training sequence trigger was added to the connection diagram unnecessarily. 2.24 [2015-06-02]: bugfix Fixed bug in Legacy mode where AUX DATA mode was set to SecondChannel instead of Mux on repeated runs. modification Increased timeouts and adjusted pattern load order to avoid issues with slow load times on M8020A with firmware >2.0. 2.23 [2015-05-19]: bugfix Fixed a bug where the error ratio mode on the N4903B error detector was not set up correctly in Legacy mode. bugfix Fixed issue where sometimes false positives were reported when checking for inconsistent N4903B error detector states. bugfix Fixed several issues with setting up the sample rate on the scope during calibration. bugfix Changed pass/fail limits for Rx data rate deviation tolerance test to better reflect the spec limits. 2.22 [2015-04-27]: modification Tested with J-BERT M8070A FW rev. 2.0.0.0 bugfix Fixed bug in voltage calibration procedure for legacy UTD revisions where TRIG OUT was not enabled on M8020A. 2.21 [2014-10-31]: modification Tested with J-BERT M8070A FW rev. 1.5.0.0 modification Adjusted connections to changed M8020A output protection. 2.20 [2014-08-12]: modification Tested with DSO FW 4.20.0008 (Windows XP) and FW 5.10.0003 (Windows 7) modification Tested with J-BERT N4903B FW rev. 7.50 and 7.60 modification Tested with J-BERT M8070A FW rev. 1.0.8.6 modification Supports N5411B SATA Tx Test Application versions 1.71 (Windows XP) and 1.80 (Windows 7) modification Supports SerialTek BusXpert version 4.0.929 new Added M8020A J-BERT support. new Added support for SATA interface u. new Added InfiniiSim integration. new Implemented new loopback training method based on SATA Link Training Suite. (The old jbistgui-based training is still available as legacy mode.) known issue When using Rx BIST Control mode 'Manual With Data Generator' in combination with jbistgui there is one additional manual step required that was not necessary before. Before loading the training sequence from jbistgui to the N4903B the user needs to manually change the 'AUX Channel Mode' on the N4903B from 'Second Channel' to 'Multiplexer Mode'. modification Changed default value of 'Use full AutoAlign' to true, because there are more DUTs that actually need it out in the field than we expected. modification Split up CDR settings into separate data rate dependent ones and moved them to the matching node. modification Increased default CDR loop bandwidth for N4903B to 7.5 MHz. modification Default CDR loop bandwidth for M8020A is DataRate/750. modification Adjusted selection of available TX tests based on scope app changes. modification Increased PowerCycleSettlingTime defaults to 10 s for devices and 15 s for hosts. modification Using a trigger does not imply forcing a power cycle on the first loopback training attempt any longer. modification In differential voltage calibration use max voltage for initial scale test check and reduce required margin to spec from 10 % to 2 % (still warn if under 10 % but above 2 %). modification Minor adjustments in IBerReader usage to better match the behavior across ValiFrame applications. modification Improved handling of instrument connection strings with non-default formats. modification Use bigger steps in de-emphasis calibration. modification Use de-emphasis calibration data in differential voltage calibration. modification Do not add OOB tests if the DataGenerator is not an N4903B and add a log message about that instead. modification Added warning that OOB tests will not work if J-BERT in connected with anything but a LAN connection. modification Changed StationConfigurator to dynamically show the currently selected instruments instead of a static image. modification Moved SSC and data rate deviation settings from 'Receiver' node to individual tests. modification Moved the 'De-Emphasis' read-only property up from the individual test procedure level to the Receiver level (still on the procedure level for calibrations). modification Changed order of calibration procedures to avoid unnecessary connection changes (moved de-emphasis calibration to after jitter calibration). modification Use consistent order for properties across all receiver tests (Error Detection, Voltage, Jitter, Data Rate, SSC). modification Use consistent SSC frequency and deviation limits throughout all receiver tests. modification Renamed property 'Use de-emphasis box' to 'Use de-emphasis', because M8020A can create de-emphasis without an external box. modification Renamed Rx BIST Control setting value from 'Manual JBERT B' to 'Manual With Data Generator' because it also covers other instruments now. modification Improved error reporting for loopback training issues. modification Improved reporting of cases where J-BERT returns inconsistent results. modification Removed option to use algorithm LogarithmicUp from jitter tolerance test (because there is no scenario where using it would make sense). modification Minor adjustments and clarifications in connection diagrams and connection description texts. bugfix Fixed a bug that sometimes caused failing loopback training to be stuck in an endless loop. bugfix Fixed a bug where sometimes loopback training retries were skipped after errors in the previous try. bugfix Fixed bug that made it impossible to use Single Frequency mode in the Receiver Jitter Tolerance Test. bugfix Fixed Excel 2013 'Run-time error 91' bug. bugfix Fixed Excel issue when setting start and stop frequency to the same value in the Receiver Jitter Tolerance Test. bugfix Fixed a bug that sometimes caused tests to completely fail when an Excel error occurred during initialization. 2.11 [2013-09-24]: bugfix Fixed a bug where depending on the station configuration trying to open the DUT parameters window would sometimes throw an exception. 2.10 [2013-09-20]: modification Tested with DSO Software Versions: 04.20.0006/WinXP, 04.50.0009/Win7 modification Tested with J-BERT Firmware Revision: 7.40 modification Supported SATA Tx Test Application (N5411B) version: 1.65.0.0 modification Supported SerialTek BusXpert version: 4.0.924 modification Added additional abort checks to improve abort responsiveness, especially during loopback training. modification Use a consistent default value (5k) for the 'Number of Frames' property for all non-compliance RX tests. This should speed up the jitter tolerance test significantly. modification Changed default behavior to do a TimeCenter whenever a full AutoAlign was done before. This should significantly improve test times especially when running tests one by one instead of several tests at once. modification Added 'Use full AutoAlign' setting that makes it possible to use the old behavior instead. This is editable in compliance mode, too. modification Changed default 'Number of Allowed Frame Errors' value for all non-compliance RX tests from 0 to 1. modification Changed default 'Use trigger for BIST training' value to false for Hosts, too. Most hosts that can be trained at all can be trained without the trigger, so the simpler setup is now the default. modification The minimum settable Random Jitter is now calculated from the available calibration data (was a fixed, relatively high value before). modification Several properties that were previously only available for some individual tests were moved to the Receiver node. They are now accessible for all RX tests and can be set in one step. ('Force Retraining', 'Always Power Cycle' and several error detector properties) modification Added data rate groups for calibrations and receiver tests to the test tree like the ones that were already there for transmitter tests. modification Some property category names were changed to make their meaning more clear: 'Generator' -> 'Data Generator', 'Analyzer' -> 'Error Detector', 'BIST-L Training' -> 'Loopback Training' modification Reorganized and extended the UI for setting parameters from the 'Configure DUT' window. new Power switch automation is now available for TX tests, too. new Added option to select the maximum number of loopback training retries. new Added option to set a defined waiting period after automatic power cycles ('Settling time', default: 3s for devices, 12 s for hosts). bugfix Fixed a bug where the receiver jitter tolerance test would not correctly handle when the J-BERT AutoAlign function reports results that are inconsistent with the real error detector state. bugfix Fixed a bug where OOB tests were not visible if the data generator was set to offline. bugfix Fixed some property description typos. 2.00 [2013-07-01]: new Added support for power switch automation (extensible, default implementations for Synaccess NP netBooter series and Koukaam NETIO-230B). modification Removed support for legacy instruments (J-BERT A, 81134A, Crescent Heart Sata Probe, Logic Analyzer, ULink Drive Master, 80000 series oscilloscope). modification Moved de-emphasis setting to 'Configure DUT'-window. modification Store calibration data separately per de-emphasis value (except for de-emphasis cal data). modification Minor optimization in loopback activation code for hosts. modification Minor UI cleanup. 1.71 [2013-05-13]: modification Updated BusXpert support to version 4.0.915. modification Use less steps for the differential voltage calibration. modification Adjusted limits and default values in Data Rate Deviation and SSC tests. modification Always show the SSC generator hardware in the connection diagrams for setups with 81134A and external SSC source, even for calibrations that do not use it. This avoids unnecessary connection changes. modification Changed loopback activation code to only ask the user for a power cycle once per test point. bugfix Fixed a bug that caused J-BERT A initialization to fail. bugfix Fixed a bug that caused an error when running several test in a single run while 81134A with external SSC source is used. 1.70 [2013-04-09]: new J-BERT can now be used for loopback training during TX tests, too. bugfix Fixed several minor bugs in connection diagrams, log messages and excel reports. bugfix Jitter calibration using EZJIT Plus did not work with DSO/X firmware version 4.10 and above. bugfix 'Save results as workbook' was not working when certain Tx tests were active. bugfix There were several possibilities to create configurations that do not make sense. modification Updated BusXpert support from version 4.0.883 to 4.0.905. modification Added property 'CDR Peaking' to Rx tests. modification Added more tolerance for slow measurement hardware. modification Improved repeatability of Rx jitter tolerance test. 1.60 [2012-09-28]: bugfix Fixed several typos in spec descriptions. bugfix Fixed several minor inconsistencies in connection diagrams. bugfix Fixed a bug that would show the wrong connection diagram for the 'Maximum J-BERT SJ Calibration' when triggered through the context menu instead of by running the procedure. bugfix Fixed a bug that made it possible to change a tx test setting in a way that would show up in the result sheet, but not actually apply to the test. modification Added external sources to connection diagram images that were only mentioned in the description before. modification Changed pattern load order to reduce average total test time. modification Use more descriptive labels for the checkboxes in the 'Configure DUT'->'SATA Parameters' window. modification Prepend 'VF_' to all file names when writing patterns to the J-BERT to avoid overwriting existing non-ValiFrame files. modification Added ability to handle subdirectories to BIST activation sequence import feature. modification Updated N5411B support from version 1.63 to 1.64. modification Updated BusXpert support from version 4.0.853 to 4.0.883. new Added option to train hosts without a trigger. new Added support for De-Emphasis Box. 1.51 [2012-07-13]: new Added a property to select which one of several search algorithms the jitter tolerance test uses. new ValiFrameRemote: Added timestamps when automatically creating names for stored result files so they do not overwrite older files. modification Explicitly control J-BERT SymbolAlign state instead of relying on automatic mode to get stable measurement results from a DUT with disparity errors in the align symbols. modification Improved error handling in communication with TX scope application. modification Reduced default value for max SJ during calibration from 500 to 400 mUI. modification Cleanup Tx scope app integration to not show options that are not possible with the available hardware. modification Removed nonsensical pseudo-precision from frequency steps and displayed results in the jitter tolerance test. bugfix Fixed inconsistencies in the precision and column width of the spec column in the Excel result display. bugfix Fixed a crash that occurred when running with J-BERT A in offline mode. bugfix Fixed a bug where Tx scope app tests were not working with the 80000 scope. bugfix Fixed a bug where differential voltage calibration was not working in offline mode for UTD 1.3 and older. bugfix Fixed a bug where SJ calibration was not working for UTD 1.3 and older. bugfix Fixed several issues with SJ calibration on J-BERT A. bugfix Fixed a bug where 1.5 G calibrations where not displayed for UTD 1.3 and older when Gen2 was selected. bugfix Fixed a typo in the description of the 'Jitter Step Size' property in the jitter tolerance test. bugfix Fixed a bug where the jitter tolerance test sometimes measured some test points twice. 1.50 [2012-04-26]: modification Avoid setting values that unnecessarily restart the J-BERT sequencer (to keep DUTs in loopback as long as possible). modification Updated TX scope app integration to version 1.63. bugfix Fixed a bug where the data generator would be actively used by the TX app despite being set to offline. bugfix Fixed a bug where analyzer patterns would not be correctly loaded onto the J-BERT. bugfix Fixed a bug where the wrong pattern was used for calibration under certain conditions. 1.41 [2012-02-10]: bugfix Fixed problem with database connection. ('Register DUT' button was not working correctly) new Updated TX scope app integration to version 1.62. 1.40 [2012-01-03]: bugfix Several minor bugfixes. bugfix Adjusted SSC generation with 81134 to work with MXG, too, instead of only with ESG. bugfix Fixed bug where data rate was not set correctly when data generator was configured to pulse generator without SSC. new Updated TX scope app integration to version 1.61.9037.0 (beta for 1.62). new Updated BusXpert integration to version 4.0.853. new Added support for UTD 1.4.3. new Added option to ignore upper voltage spec limits. new Added support for DUT BIST mode activation through custom DLL. new Added property to limit frequency in SJ cal. new Added option to include compliance frequencies in jitter tolerance test. modification Renamed checkbox label in Station Configurator from 'SSC' to 'SSC generators available'. modification Moved 'Use Switch'-checkbox from Station Configurator to Configure DUT window. modification Optimized instrument initialization between tests to reduce total test time. modification SJ Cal now handles EZJit problems more tolerantly. modification Use separate calibration file sets for different data generator types. 1.33 [2011-08-31]: bugfix Fixed a problem in RJ Calibration that could lead to misleading error messages when the Scope returns inconsistent data. bugfix Fixed scaling issue in Differential Voltage Calibration data display. bugfix Fixed problem with re-initializing BIST-L during Data Rate Deviation Test. 1.32 [2011-08-24]: bugfix Fixed cabling inconistency in connection diagrams with SerialTek BusXpert error detector. modification Made 3G TX jitter tests available when the DUT is configured to 6G. modification Implemented common sort order for property categories. new Added support for devices that use protocol layer loopback. 1.31 [2011-08-05]: modification Made 1.5G tests available in expert mode when DUT is configured to 3G for UTD1.2 and 1.3. modification Moved OOB tests to separate category. bugfix Use LFTP instead of HFTP as default pattern for risetime and falltime tests with UTD1.4 and higher. bugfix Fixed problem with saving TX test results in an excel workbook. bugfix Workaround for scope reporting obviously wrong jitter values during SJ calibration. bugfix Fixed problem with minimum voltage during differential voltage calibration. 1.30 [2011-07-08]: bugfix Several minor bugfixes. bugfix Fixed scaling issues that made some windows hard to use on systems with specific DPI settings. bugfix Activate jitter during UTD 1.4 voltage calibration. bugfix Use correct measurement method for UTD 1.4 voltage calibration. modification Adjusted J-BERT synchronization and alignment settings. modification Use stricter checks to avoid false positives when testing if a DUT is in loopback. modification Extended sinusoidal jitter calibration to cover a wider jitter amplitude and frequency area if possible with the available hardware. modification Adjusted voltage spec limits for UTD 1.4.2. modification Updated J-BERT based BIST-L activation for devices. new Added new voltage calibration procedure for UTD 1.4.2. new Added semi-automatic mode for J-BERT based BIST-L activation for users who want full control during each running test. new Added option to import custom settings for J-BERT based BIST-L activation. new Added J-BERT based BIST-L activation for hosts. 1.23 [2011-04-19]: bugfix Fixed BusXpert integration (including Visual C++ 2010 Runtime DLLs) 1.22 [2011-03-18]: modification TX scope app integration: support version 1.20 and 1.50 depending on oscilloscope type 1.21 [2011-03-09]: modification Adjust internal parameters to make sure tests work with oscilloscope firmware version 3.0. bugfix Fixed Station Configurator inconsistencies that made it possible to select nonsensical instrument combinations. bugfix Cleaned up several minor issues with connection diagrams. bugfix Cleaned up several minor issues with the BusXpert integration. bugfix Cleaned up several minor issues with the TX app integration. bugfix Removed 'Register' button when database option is not available. new Added option to use user-defined custom BER reader. new Added additional flags to control BIST-L training behaviour modification Updated supported BusXpert version to 3.0.790 bugfix Reduced max DJ from 610 to 600ps for JBERT B, because some models only supports 600ps. 1.20 [2010-11-11]: modification Updated supported BusXpert version to 2.2.714 modification Adjusted FER support to changed J-BERT firmware syntax. new Added J-BERT based BIST-L activation (only for devices, hosts not supported yet). new Changed pattern/sequence handling to enable advanced customers to use special sequences. new Added user editable 'DataRate Mode' property to control if BusXpert DataRate is set to a specific value or to 'auto'. new Added user editable 'Transition Density' property for J-BERT error detector. new Added checks to make sure required calibration data is available and internally consistent. bugfix Fixed problem with MessageBoxes not being correctly suppressed when using the remote interface modification Improved Differential Voltage Calibration to work with more setups and allow higher voltage levels where possible. new Added 'Recovery Time' property to control the delay between signal stress parameter changes and measurements. 1.19 [2010-07-29]: new new release 1.18 [2010-05-28]: bugfix Added missing connection diagrams new Support for JBert B Frame Error Counter feature 1.16 [2009-11-24]: modification Split characterization tests and ordered them by data rate new Support for SerialTek BusXpert frame error counter (enables automated testing up to 6G) 1.15 [2009-07-07]: new Support for UTD1.4, New compliance tests: RSG-03 (6G receiver jitter tolerance test) RSG-05 (receiver stress test at datarate +350ppm) RSG-06 (receiver stress test with SSC) 1.14 [2009-02-10]: bugfix Jitter Calibration Procedures are aborted with an error when the jitter is too high and cant be measured be the scope bugfix Differential Voltage Calibration works now with 2 and 4ALIGN Framed COMP pattern for UDT1.2 and UDT1.3 bugfix FramedCOMP4AlignUTD_1.2 and FramedCOMP2AlignUTD_1.3 pattern does not work for J-BERT setup 1.13 [2008-10-20]: new OOB Tests for J-BERT setup with additional 81134A as OOB source new SSC as new test parameter (only for J-BERT) new Data Rate Deviation as new test parameter new J-BERT as error detector with BER tests. Only characterization, no compliance. new Bit Error control of data generator from JBERT new ISI is included (optional) bugfix Rcvr Jitter Tolerance Test: Hysteresy of DUT's CDR is considred in the search algorithm 1.12 [2008-04-29]: new Framed COMP 4-Align pattern for UTD1.3 modification Faster random and total jitter calibration new Test parameters from N5411A application for PHY, TSG, OOB tests can be changed over N5990A GUI new Support for J-BERT as datagenerator with integrated jitter 1.11 [2008-03-11]: modification Rcvr Jitter Tolerance Test: Max SJ frequency is increased from 80 to 240 MHz if 81150A is used is as sine source new Intergration of N5411A SATA TSG and OOB tests modification Max total jitter in Rcvr Jitter Tolerance test for 3.0Gbit/s is increased from 1.0 to 1.4UI new Calibration data from a previous session can be display in excel sheets and will be included in the Excel workbook 1.10 [2008-02-01]: new ULINK DriveMaster 2008 integration for automatic BIST-L activation new Switch Automation for DUTs which do not support disconnect 1.03 [2008-01-21]: bugfix Valiframe does not connect to instruments bugfix Agilent N81150A support as noise and sine source new Support for spec version UTD1.3 1.00 [2008-01-21]: modification Jitter tolerance test reintialize BIST-L after each SJ-frequency steps when DUT does not retransmit frames. new eSata (m Spec) support new Alternative 2-Align test pattern for RSG tests