===== ValiFrame USB4 Module ===== ======================================================================================================================= 2.1 [released 2022-03-18] ======================================================================================================================= 2.1.2.2 [available 2022-05-12] prerequisite To run SigTest, a minimum of 16GB RAM is required, 32GB RAM is recommended prerequisite Windows 10 (64 bit), English, version 2004 or newer prerequisite Microsoft .NET Framework 4.8 or newer prerequisite Keysight IO Libraries Suite 18.1 or newer supported Microsoft Office Excel 2016, English supported M8041A/M8062A, M8070B FW rev. 8.5.380.14 supported M8045A/M8054A, M8070B FW rev. 8.5.380.14 supported DSO-X/V/Z, FW rev. 6.71.00202 supported UXR1102A, FW rev. 11.25.00202 supported USB4_SigTest rev 0.70 supported Matlab Runtime Compiler R2021b (9.11) supported USB4 ETT 1.0.1 modification Filestream is not closed now when creating a semaphore file bugfix In M8020A systems, the pre-Cursor2 was set to 1.00 dB for all TxFFE presets instead of 0.00 dB bugfix Fixed slight rounding inaccuracy for preset 5 known issue In rare cases, an exported Excel file seems to be blocked by another user. Re-opening Excel helps known issue Input eye calibration sometimes fails caused by an "Index out of range" exception in SigTest 2.1.1.4 [available 2022-04-12] prerequisite To run SigTest, a minimum of 16GB RAM is required, 32GB RAM is recommended prerequisite Windows 10 (64 bit), English, version 2004 or newer prerequisite Microsoft .NET Framework 4.8 or newer prerequisite Keysight IO Libraries Suite 18.1 or newer supported Microsoft Office Excel 2016, English supported M8041A/M8062A, M8070B FW rev. 8.5.380.14 supported M8045A/M8054A, M8070B FW rev. 8.5.380.14 supported DSO-X/V/Z, FW rev. 6.71.00202 supported UXR1102A, FW rev. 11.25.00202 supported USB4_SigTest rev 0.70 supported Matlab Runtime Compiler R2021b (9.11) supported USB4 ETT 1.0.1 modification Removed M8194A and M8196A as supported CMI sources modification Offline values for input eye width at TP3 are now calculated with respect to jitter values modification Keep the BERT settings at the end of a procedure and only switch off the outputs bugfix Checkbox to choose the FrequencyVariation Training Test 1.01 was sometimes shown by mistake bugfix Some user changes in the MultiError Burst test were overwritten while running the test bugfix In special cases, some user edited parameter were not set correctly in the BERT known issue In rare cases, an exported Excel file seems to be blocked by another user. Re-opening Excel helps known issue Input eye calibration sometimes fails caused by an "Index out of range" exception in SigTest 2.1.0.25 [available 2022-03-18] prerequisite To run SigTest, a minimum of 16GB RAM is required, 32GB RAM is recommended prerequisite Windows 10 (64 bit), English, version 2004 or newer prerequisite Microsoft .NET Framework 4.8 or newer prerequisite Keysight IO Libraries Suite 18.1 or newer supported Microsoft Office Excel 2016, English supported M8041A/M8062A, M8070B FW rev. 8.5.380.14 supported M8045A/M8054A, M8070B FW rev. 8.5.380.14 supported DSO-X/V/Z, FW rev. 6.71.00202 supported UXR1102A, FW rev. 11.25.00202 supported USB4_SigTest rev 0.70 supported Matlab Runtime Compiler R2021b (9.11) supported USB4 ETT 1.0.1 new Support of signal frequency variations training test according to CTS 1.02 (clock switch test) new Visual configuration of ETTs Swap Lanes parameter new Added Verification procedures for SigTest calibration modification Support of new SigTest 0.70 modification SigTest is not required if no scope is connected. No warning is shown modification Added ability to the CustomBerTest to use customized values for swing and jitter modification Adapted the start value of the CMI amplitude in a setup M8040A with AWG modification Improved handling of the ETT calling process modification More efficient adjustment of the input eye width at TP3 modification Added "margin" column to the JitterToleranceCharacterization test modification Additional logging during input eye calibration @TP3 modification Reduced the probability of selecting a wrong SigTest executable modification Removed the ErrorCounterCheck in the 2nd run of the compliance test. It was obsolete modification The tested lane parameter in a USB4-ETT call is adapted to the SwapLanes parameter to avoid the need to flip the fixture modification The former calibration folder 'M8054A' is now called 'AWG'. All old calibration files are copied in there modification Re-initiate the USB4 controller according to the chosen "Reset DUT" method modification Link training for Error burst test can be done with a PJ amplitude ramping up bugfix Excel export failed sometimes bugfix If no SigTest was available, Valiframe changed silently to the scope method without informing the user bugfix Added some missing calibration table dependencies bugfix Invalid SigTest jitter results were taken as valid "0" in the DDJ calibration and thus, the wrong Tx EQ preset was chosen for all TP3' calibrations bugfix The Sigtest executable was always configured with 'USB4SigTest.exe', independent of the setting in the StationConfigurator bugfix MultiErrorBurst test was accidentally running a BER test with 10s before starting the real BER test bugfix The amplitude set in the BERT during sensitivity test at TP3 was incorrect bugfix Amplitude swing of the M8020A was incorrect for TxEq preset 15 bugfix Sometimes the access to USB4TestToolServer in a VPN environment did not work bugfix Ramping up the PJ in MultiErrorBurst test was done with PJ glitches, which will cause link break known issue In rare cases, an exported Excel file seems to be blocked by another user. Re-opening Excel helps known issue Input eye calibration sometimes fails caused by an "Index out of range" exception in SigTest ======================================================================================================================= 2.0 [released 2021-07-02] ======================================================================================================================= 2.0.5.1 [available 2022-01-12] prerequisite To run SigTest, a minimum of 16GB RAM is required, 32GB RAM is recommended prerequisite Windows 10 (64 bit), English, version 2004 or newer prerequisite Microsoft .NET Framework 4.7.1 or newer prerequisite Keysight IO Libraries Suite 18.1 or newer supported Microsoft Office Excel 2016, English supported M8041A/M8062A, M8070B FW rev. 8.0.200.18 supported M8045A/M8054A, M8070B FW rev. 8.0.200.18 supported DSO-X/V/Z, FW rev. 6.60.0601 supported UXR1102A, FW rev. 10.25.01302 and 11.15.00001 supported USB4_SigTest rev 0.6 supported USB4 ETT 1.0.1 bugfix In rare cases, an out of range exception was thrown while running the Sensitivity Test (ExpertMode) known issue Signal frequency variations training test not supported by M8040A system (not enough PJ capability of M8045A module) 2.0.4.2 [available 2021-12-28] prerequisite To run SigTest, a minimum of 16GB RAM is required, 32GB RAM is recommended prerequisite Windows 10 (64 bit), English, version 2004 or newer prerequisite Microsoft .NET Framework 4.7.1 or newer prerequisite Keysight IO Libraries Suite 18.1 or newer supported Microsoft Office Excel 2016, English supported M8041A/M8062A, M8070B FW rev. 8.0.200.18 supported M8045A/M8054A, M8070B FW rev. 8.0.200.18 supported DSO-X/V/Z, FW rev. 6.60.0601 supported UXR1102A, FW rev. 10.25.01302 and 11.15.00001 supported USB4_SigTest rev 0.6 supported USB4 ETT 1.0.1 modification Re-initiate the USB4 controller according to the chosen "Reset DUT" method known issue Signal frequency variations training test not supported by M8040A system (not enough PJ capability of M8045A module) 2.0.3.8 [available 2021-11-22] prerequisite To run SigTest, a minimum of 16GB RAM is required, 32GB RAM is recommended prerequisite Windows 10 (64 bit), English, version 2004 or newer prerequisite Microsoft .NET Framework 4.7.1 or newer prerequisite Keysight IO Libraries Suite 18.1 or newer supported Microsoft Office Excel 2016, English supported M8041A/M8062A, M8070B FW rev. 8.0.200.18 supported M8045A/M8054A, M8070B FW rev. 8.0.200.18 supported DSO-X/V/Z, FW rev. 6.60.0601 supported UXR1102A, FW rev. 10.25.01302 and 11.15.00001 supported USB4_SigTest rev 0.6 supported USB4 ETT 1.0.1 new Full functional SigTest calibration of the Input eye at TP3 modification Added a TJ check procedure at TP3' eye height calibration modification Use SigTest as default calibration method modification Set the supported CTS version to 1.02 modification Allow to select the SigTest executable instead of insisting on a dedicated filename modification Adapt the default filename of the USB4Sigtest executable to the newest version from USB-IF modification Use the crosstalk option in ETT calls to always enable the DUTs TX outputs modification Removed unwanted interactions with the Wilder_Controller_API modification The amount of repetitions of the SignalFrequencyVariation test is now adjustable modification Adaptions to support the M8194A module bugfix Sensitivity test could not be done down to the smallest possible generator swing bugfix With test mode "Manual DUT Interaction", the USB4ElectricalTestTool could not access the USB4 controller bugfix In rare cases, the eye width at TP3 could not be adjusted because of undefined jitter step sizes bugfix Gen4 options were sometimes visible in preliminary installer versions bugfix Wrong check of the ETTs executable path if a RemoteInstrumentsServer is used bugfix Allow TX preset 15 during tests, although it's not included in DDJ calibration bugfix The used SigTest version was not saved into the cal table known issue Signal frequency variations training test not supported by M8040A system (not enough PJ capability of M8045A module) 2.0.2.2 [available 2021-09-17] prerequisite To run SigTest, a minimum of 16GB RAM is required, 32GB RAM is recommended prerequisite Windows 10 (64 bit), English, version 2004 or newer prerequisite Microsoft .NET Framework 4.7.1 or newer prerequisite Keysight IO Libraries Suite 18.1 or newer supported Microsoft Office Excel 2016, English supported M8041A/M8062A, M8070B FW rev. 8.0.200.18 supported M8045A/M8054A, M8070B FW rev. 8.0.200.18 supported DSO-X/V/Z, FW rev. 6.60.0601 supported UXR1102A, FW rev. 10.25.01302 and 11.15.00001 supported USB4_SigTest rev 0.6 supported USB4 ETT 1.0.1 modification Display the used SigTest version in the reports modification Copy only the content of the SigTest top directory into Valiframes workspace bugfix ValiFrame Remote Interface was reporting an InvalidProgramException while ending the application known issue Tuning the eye height and width at TP3 does not work with SigTest known issue Infiniium version 11.15.00001 is not fully tested known issue Support of AWG M8194A is not fully tested known issue Signal frequency variations training test not supported by M8040A system (not enough PJ capability of M8045A module) 2.0.1.7 [available 2021-08-17] prerequisite To run SigTest, a minimum of 16GB RAM is required, 32GB RAM is recommended prerequisite Windows 10 (64 bit), English, version 2004 or newer prerequisite Microsoft .NET Framework 4.7.1 or newer prerequisite Keysight IO Libraries Suite 18.1 or newer supported Microsoft Office Excel 2016, English supported M8041A/M8062A, M8070B FW rev. 8.0.200.18 supported M8045A/M8054A, M8070B FW rev. 8.0.200.18 supported DSO-X/V/Z, FW rev. 6.60.0601 supported UXR1102A, FW rev. 10.25.01302 and 11.15.00001 supported USB4_SigTest_rev0p5 supported USB4 ETT 0.9.8 modification Removed the verification procedures for SigTest, since they are not helpful with the current v0.5 modification Added TJ measurement to the verification at TP3' for signal analyzer type "Scope" modification Renamed the "Rx Customer BER Test" modification Placed the optional extra parameters in the USB4ETT call at the end; they can be used to overwrite default parameters bugfix The ValiFrame Remote Interface was inaccessible by e.g. Python scripts due to wrong license protection bugfix In some rare cases, Valiframe tried to set an invalid SJ amplitude on the BERT during a jitter tolerance characterization test bugfix Offline TBT tests were not properly handling the ErrorCounterTest step bugfix Fixed inaccuracy in the design of the ConfigureDUT dialog bugfix Bundled licenses were not shown in the ValiFrame about window known issue Tuning the eye height and width at TP3 does not work with SigTest known issue Infiniium version 11.15.00001 is not fully tested known issue Support of AWG M8194A is not fully tested known issue Signal frequency variations training test not supported by M8040A system (not enough PJ capability of M8045A module) known issue The ValiFrame Remote Interface is reporting an InvalidProgramException while ending the application. This does not impact correct functionality information Updated CodeMeter Runtime to version 7.30 to fix vulnerabilities CVE-2021-20093 and CVE-2021-20094 as well as the inaccessibility of ValiFrame Remote Interface 2.0.0.10 [available 2021-07-02] prerequisite To run SigTest, a minimum of 16GB RAM is required, 32GB RAM is recommended prerequisite Windows 10 (64 bit), English, version 2004 or newer prerequisite Microsoft .NET Framework 4.7.1 or newer prerequisite Keysight IO Libraries Suite 18.1 or newer supported Microsoft Office Excel 2016, English supported M8041A/M8062A, M8070B FW rev. 8.0.200.18 supported M8045A/M8054A, M8070B FW rev. 8.0.200.18 supported DSOX, FW rev. 6.60.0601 supported UXR1102A, FW rev. 10.25.01302 and 11.15.00001 supported USB4_SigTest_rev0p5 supported USB4 ETT 0.9.8 new Support of instrument calibrations with SigTest new Support of M8194A as CMI source new Application is running in full x64 mode new Check for the right instrument firmware revisions (as mentioned above) new Display the expiration period of the maintenance license modification Update licensing and protection libraries modification Clarifications in the connection diagram with M8040A and VNA modification By default, only Lane0 is calibrated, to save a lot of calibration time modification The selection made for scope connection and Lane1 calibration is saved modification Do not insist on a specific folder name and allow any arbitrary location of the SigTest executable modification The frequency at which to measure the insertion loss with the VNA is displayed modification The USB4TestToolServer has been updated to the newest process handling code bugfix The DUT property of having a multi tab DFE retimer was not saved with the project file bugfix Valiframe GUI was sometimes frozen for a while if lengthy scope measurements were ongoing bugfix In rare cases, the CMI calibration passed, even if the CMI amplitude was too high known issue Tuning the eye height and width at TP3 does not work with SigTest known issue Infiniium version 11.15.00001 is not fully tested known issue Support of AWG M8194A is not fully tested known issue Signal frequency variations training test not supported by M8040A system (not enough PJ capability of M8045A module) ======================================================================================================================= 1.3 [released 2021-04-16] ======================================================================================================================= 1.3.3 [available 2021-06-01] prerequisite Windows 10 (64 bit), English, version 2004 or newer prerequisite Microsoft .NET Framework 4.7.1 or newer prerequisite Keysight IO Libraries Suite 18.1 or newer supported M8041A/M8062A, M8070B FW rev. 7.2.40.2 and 7.2.140.2 supported M8045A/M8054A, M8070B FW rev. 7.2.40.2 and 7.5.700.8 supported DSOX/V/Z, FW rev. 6.55.00901 and 06.60.00403 supported UXR1102A, FW rev. 10.25.00702 and 10.25.01302 supported USB4 ETT 0.9.8 supported Microsoft Office Excel 2016, English bugfix The application crashed during tests done with manual DUT interaction bugfix The additional parameters were not passed to all calls of the ETT, so the jitter tolerance characterization test failed for some DUTs known issue Due to the lack of a suitable DUT, error burst test is not completely tested and may not work properly known issue Testing TBT automated scripts: TenLira 4.10 does not support the 'uC_Reset.tbc' script 1.3.2 [available 2021-05-18] prerequisite Windows 10 (64 bit), English, version 2004 or newer prerequisite Microsoft .NET Framework 4.7.1 or newer prerequisite Keysight IO Libraries Suite 18.1 or newer supported M8041A/M8062A, M8070B FW rev. 7.2.40.2 and 7.2.140.2 supported M8045A/M8054A, M8070B FW rev. 7.2.40.2 and 7.5.700.8 supported DSOX/V/Z, FW rev. 6.55.00901 and 06.60.00403 supported UXR1102A, FW rev. 10.25.00702 and 10.25.01302 supported USB4 ETT 0.9.8 supported Microsoft Office Excel 2016, English known issue Due to the lack of a suitable DUT, error burst test is not completely tested and may not work properly known issue Testing TBT automated scripts: TenLira 4.10 does not support the 'uC_Reset.tbc' script 1.3.1 [available 2021-05-14] supported M8041A/M8062A, M8070B FW rev. 7.2.40.2 and 7.2.140.2 supported M8045A/M8054A, M8070B FW rev. 7.2.40.2 and 7.5.700.8 supported DSOX/V/Z, FW rev. 6.55.00901 and 06.60.00403 supported UXR1102A, FW rev. 10.25.00702 and 10.25.01302 supported USB4 ETT 0.9.7 modification Display the search algorithm parameters of the jitter tolerance characterization in the report modification Restrict the parameter "Step Size Ratio" in the jitter tolerance characterization to a range 1...100 bugfix In some rare cases, the search algorithm in the jitter tolerance characterization test could not calculate meaningful step sizes known issue Due to the lack of a suitable DUT, error burst test is not completely tested and may not work properly known issue Testing TBT automated scripts: TenLira 4.10 doesn't support the 'uC_Reset.tbc' script 1.3.0 [available 2021-04-16] supported M8041A/M8062A, M8070B FW rev. 7.2.40.2 and 7.2.140.2 supported M8045A/M8054A, M8070B FW rev. 7.2.40.2 and 7.5.700.8 supported DSOX/V/Z, FW rev. 6.55.00901 and 06.60.00403 supported UXR1102A, FW rev. 10.25.00702 and 10.25.01302 supported USB4 ETT 0.9.7 modification Full support of USB4 ETT in all tests; partial support in the error burst test modification Changes in "Signal Frequency Variations Training Test" according to new CTS 1.01 (run the test 20 times and use PRBS15 instead of PRBS31) modification Re-ordered the test tree to have less reconnecting during a complete calibration or Rx-test run modification Display the port address numbers instead of port names in the TreeView modification Removed the aggressor from the connection diagrams and from the ETT calls modification M8062A module is not enabled at Valiframe's initialization to shorten the startup time modification Added a parameter to skip complete BERT initialization during the repetitions of a test modification If measured eye height at TP3' is bigger than the applied PRBS swing, now only a warning is printed out; the test may still pass modification Eye height calibration at TP3' starts with a slightly smaller amplitude modification Run the ETT directly as a process instead of launching it inside a cmd-shell modification Removed the output polarity parameter from all tests. Output is now always set to "normal" bugfix ErrorCounter check was missing in the compliance BER test bugfix Connection diagram for Gen3 tests at TP3' was showing 2.0m USB-C cable, which will not work with USB4 ETT bugfix Manual change of the SJ Frequency in the Sensitivity test had no effect. Test was always performed at 100MHz bugfix Exception occurred in a M8040A setup having modules M8054A and M8046A bugfix Initial PJ amplitude in the jitter tolerance characterization was wrong known issue Due to the lack of a suitable DUT, error burst test is not completely tested and may not work properly known issue Testing TBT automated scripts: TenLira 4.10 doesn't support the 'uC_Reset.tbc' script ======================================================================================================================= 1.2 [released 2020-10-31] ======================================================================================================================= 1.2.0.6_Beta [available 2020-10-09] new Support of USB4 CTS 1.0 new ErrorBurst test now runs on M8040A for all kind of DUTs modification Always use random jitter band width of 500MHz modification Allow different types of resetting the DUT during Rx tests tested with TenLira 3.16.0 (recommended) tested with TenLira 4.10.0.0 bugfix The initial Tx preset was sometimes wrong for TP3' Rx tests 1.2.0_Beta05 [available since 2020-10-01] Information Updated CodeMeter Runtime to version 7.10a to fix vulnerabilities CVE-2020-14513, CVE-2020-14519, CVE-2020-14509, CVE-2020-14517, CVE-2020-16233, and CVE-2020-14515 bugfix Swapped fixtures in the connection diagram for insertion loss calibration 1.2.0_Beta04 [available since 2020-09-21] new Testing of up to 64 ports of a DUT new Additional test procedures to check the USB4 ETT installation and environment bugfix Working with the semaphore file of USB4 ETT probably didn't work modification Configuring of the ISI source (physical trace or internal M8020A-emulation) in the ConfigureDUT modification Improved process handling 1.2.0_Beta03 [available since 2020-08-20] bugfix Don't access the Wilder Controller API while executing the USB4 ETT, they interfere with each other new Adapt the TestToolServer to support the USB4 ETT on a remote PC modification Log the outputs of each CLI call into a single file in C:\Users\Public\Documents\BitifEye\USB4ScriptLog 1.2.0_Beta02 [available since 2020-08-14] bugfix The USB4ElectricalTestToolCLI.exe is not a real standalone executable, it only runs within a cmd prompt modification Disable the (not working) flavors of the ErrorDetectorETT 1.2.0_Beta01 [available since 2020-08-14] modification First very rough version of USB4 ETT support known issue Tested only with recorded ETT outputs, no controller was available during implementation known issue Based on Valiframe USB4 1.1, which is completely tested but not officially released ======================================================================================================================= 1.1 [released 2020-08-24] ======================================================================================================================= 1.1.0 [available 2020-08-24] tested with M8041A/M8062A, M8070B FW rev. 7.2.40.2 tested with M8045A/M8054A, M8070B FW rev. 7.2.40.2 tested with M8040A, M8070B FW rev. 7.2.40.2 tested with DSOX, FW rev. 6.55.00702 tested with DSA-Z, FW rev. 6.55.00702 tested with UXR1102A, FW rev. 10.25.00702 bugfix The initial PRBS amplitude of M8040 sometimes was too low in setups with PickOffTees and splitter bugfix Assigned Tx preset at the TP3 eye calibration was not always correct bugfix Assigned Jitter was not always correct bugfix Separate CTLE calibration needed for each jitter frequency bugfix Due to rounding, DFE sometimes was configured to values slightly above 50 mV bugfix Use the DFE settings found during CTLE calibration for TP3 eye calibration instead of reconfigure DFE at each measurement bugfix CTLE configuration on the scope must be "Equalize in place", not "Display as function" bugfix Check for monotony at EyeHeight calibration at TP3 was not working correct bugfix Don't show ISI properties in TP3' calibrations bugfix Don't query the chip type in manual USB4 tests (there are no predefined chip types for USB4) bugfix Jitter tolerance characterization sometimes exceeded the allowed PJ limits of the BERT bugfix Confusing description in the connection diagram of TP3 test procedures bugfix The query for max PJ in the MultiErrorBurstTest sometimes returned wrong and too low value bugfix If running tests via TestScriptServer, sometimes the tempfile could not be accessed by the TclScript new Added step to evaluate the intrinsic RJ of the scope new Added step to calibrate the channel insertion loss at TP3 (required ISI trace or internal ISI) new Using Infiniium eye height measurement method instead of eye mask measurements new Added summary tables to each calibration test point new Handling of outliers measurement results in the input eye calibration at TP3 modification Make external ISI as default settings when using M8020A system modification Use pure instrument set values in cal tables and graphs modification Improved the ordering and categorizing of parameters in the reports modification Increased the step size in AC CommonMode calibration to have better monotonic behavior modification Smaller step size for the final Input Eye Calibration at TP3 to have better result distribution modification Better columns / x-axis name for signal amplitudes modification Update instrument images modification Repeat the Eye width calibration, before it would fail because of EyeHeight out of spec limits modification Don't report dropped eye measurements in the final Input Eye Width calibration modification Adding extra wait statement after the data acquisition step. This gives more stable results and significant bigger eyes modification Repeat the DFE AutoDelay several times to avoid uncompleted DFE configuration modification Use the new defined Tx preset 14 modification Timing improvements in the eye height measurement at TP3' modification Don't complain about USB connections to the scope, it's as fast as hislip modification Don't require adjustable ISI license for the transition time adaption known issue Error Burst Test may not work for every DUT on M8040A known issue FrequencyVariation test not supported by M8040A system (not enough PJ capability of M8045A module) known issue Captive devices not included in v1.1 because of outdated CTS known issue PDO testing is not supported due to missing functionality in Wilder TR controller API ======================================================================================================================= 1.0 [released 2020-04-17] ======================================================================================================================= 1.0.1 [available 2020-05-26] modification More prominent indication of the used fixture type in the connection diagrams modification Explicit call for tclsh85 instead of calling tclsh to avoid the usage of wrong tcl versions bugfix iTBT DUTs were not recognized correctly, when testing with TBT proprietary scripts 1.0.0 [available since 2020-04-17] tested with J-BERT M8045A+M8196A and firmware M8070B FW rev. 6.7.500.6 tested with J-BERT M8041A+M8062A and firmware M8070B FW rev. 6.7.500.6 tested with UXR0134A FW rev. 10.12.05302 tested with DSA-Z FW rev. 6.50.01004 tested with DSA-V FW rev. 6.50.01004 tested with 81160A, FW 2.0.0.0-2.6 tested with N5181A MXG, FW A.01.50 tested with Legacy controller and TBT electrical scripts 0.8.9.1 new Adapted to USB4 CTS 0.96 (Jan 30, 2020) new Changed to BLM (BitifEye License Manager) licensing known issue RJ LowPass Bandwidth of J-BERT M8041A+M8062A at 10.0G and 10.3125G is limited to 500MHz known issue FrequencyVariation test not supported by M8040A system (not enough PJ capability of M8045A module) known issue Captive devices not included in v1.0 because of outdated CTS known issue PDO testing is not supported due to missing functionality in Wilder TR controller API known issue Correlation of UXR Sr with DSO-V/Z is not approved